{"product_id":"cc-tdob11-51308373-175-honeywell-digital-output-module","title":"CC-TDOB11 51308373-175 Honeywell Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TDOB11 51308373-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TDOB11\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete 24 VDC signal switching and field actuation execution within Honeywell Experion PKS Series C DCS platforms. It drives solenoid valves, interposing relays, and status indicators directly from the system backplane bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TDOB11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51308373-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e30 x 21.6 x 2.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane and 24 VDC bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Series C DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated backplane route to Ethernet controller interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TDOB11 module incorporates dedicated galvanically isolated channels to prevent cross-talk and transient voltage spikes from reaching the primary controller logic. Internal optocouplers decouple field-side 24 VDC switching noise from the internal processing core. Channel-to-channel and channel-to-system isolation barriers protect the backplane from ground loops, field wiring faults, and induced electromagnetic interference across long control loop runs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CC-TDOB11 digital output module be hot-swapped while the IOTA rack remains powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports live insertion and removal (hot-swapping) on an active I\/O Termination Assembly (IOTA) without interrupting backplane communication or disturbing neighboring active modules.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle output circuit short circuits or field overload conditions?\u003c\/p\u003e\n\u003cp\u003eA: The digital output circuitry incorporates current-limiting mechanisms and channel isolation designed to isolate field faults, preventing localized electrical shorts from compromising the entire backplane assembly.\u003c\/p\u003e\n\u003cp\u003eQ: Is external 24 VDC field wiring wired directly to the front face of the module?\u003c\/p\u003e\n\u003cp\u003eA: No. Field power wiring and signal output conductors connect directly to the underlying IOTA terminal blocks. The CC-TDOB11 module establishes electrical connectivity via robust backplane pin connectors upon mechanical installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the corresponding field circuit loop power if required by site safety protocols prior to mechanical installation.\u003c\/li\u003e\n\u003cli\u003eAlign the CC-TDOB11 module PCB edge connectors with the designated card guides on the Honeywell Series C IOTA board.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the slot until the multi-pin backplane connectors seat completely into the IOTA mating header.\u003c\/li\u003e\n\u003cli\u003eSecure any integrated mechanical retention screws to maintain solid grounding and vibration resistance.\u003c\/li\u003e\n\u003cli\u003eConfirm that all field cabling tied to the IOTA terminal strips utilizes single-point shield grounding to avoid ground loop current interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52346319765800,"sku":"CC-TDOB11 51308373-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-TDOB1151308373-175_Cocoai.png?v=1788848390","url":"https:\/\/www.powerdcs.com\/es\/products\/cc-tdob11-51308373-175-honeywell-digital-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}