{"product_id":"fc-bsdol-04uni-honeywell-range-setting-module-1","title":"FC-BSDOL-04UNI | Honeywell | Range-Setting Module","description":"\u003cp\u003eConfigured for current sense range setting and output loop calibration in Honeywell Safety Manager SC platforms, the \u003cstrong\u003eHoneywell FC-BSDOL-04UNI\u003c\/strong\u003e (\u003cstrong\u003eFC-BSDOL-04UNI\u003c\/strong\u003e Range-Setting Module) provides direct physical\/electrical execution across four loop-monitored output channels. It mounts directly onto the programming connectors (Px) of the I\/O backplane to adjust lead breakage detection thresholds for connected output modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-BSDOL-04UNI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 60 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C (-4 to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Setting Resolution\u003c\/td\u003e\n\u003ctd\u003eUp to +\/-0.596 accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Channels\u003c\/td\u003e\n\u003ctd\u003e4 loop-monitored output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager SC, SDOL systems (e.g., SDOL-0424)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Signal Processing Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe FC-BSDOL-04UNI module integrates precise current sense adjustments to prevent false lead breakage detection in field output circuits. Built for integration with 4-20 mA HART loop protocol architectures and discrete safety driver outputs, the hardware provides channel-to-channel isolation to prevent electrical fault propagation across field wiring loops. In redundant output configurations involving SDOL-0424 modules, a single FC-BSDOL-04UNI serves both primary and secondary channels to maintain consistent range calibration across the safety system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the FC-BSDOL-04UNI module physically mounted to the Safety Manager chassis?\u003c\/p\u003e\n\u003cp\u003eA: The module connects directly to the dedicated programming connector (Px) interface on the I\/O backplane without external wiring harnesses.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle range-setting operations in redundant output configurations?\u003c\/p\u003e\n\u003cp\u003eA: In redundant SDOL module setups, a single FC-BSDOL-04UNI module provides unified range setting across both redundant output channels.\u003c\/p\u003e\n\u003cp\u003eQ: Does the RS-485 communication interface require separate power cabling?\u003c\/p\u003e\n\u003cp\u003eA: No, operating power of 24 VDC and communication paths are routed through the backplane programming connector interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Connection:\u003c\/strong\u003e Align the board interface with the dedicated programming connector (Px) on the Safety Manager SC backplane. Press firmly to seat the pins, ensuring no pins are bent during insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Setup:\u003c\/strong\u003e Verify that the single FC-BSDOL-04UNI module is correctly mapped across both SDOL-0424 modules when configured for redundant output operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Ensure the rack chassis grounding strip is connected to the cabinet earth bar to prevent common-mode electrical noise from affecting range-setting accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain adequate clearance around the module to allow convective heat dissipation within the rated operating temperature limit of -20 to +70 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52723125584168,"sku":"FS-BSDOL-04UNI","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FS-BSDOL-04UNI_Cocoai.png?v=1790068571","url":"https:\/\/www.powerdcs.com\/es\/products\/fc-bsdol-04uni-honeywell-range-setting-module-1","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}