FC-IOCHAS-0003R Honeywell Redundant I/O Chassis

Specifications

  • Manufacturer: Honeywell

  • Product No.: FC-IOCHAS-0003R

  • Condition: 10 Artículos en stock

  • Product Type: I/O Chassis

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 8500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Detalles de producto

Descripción

Configured for high-availability backplane routing and fault-tolerant signal execution in Honeywell Safety Manager platforms, the Honeywell FC-IOCHAS-0003R (FC-IOCHAS-0003R Redundant I/O Chassis) provides direct physical/electrical execution. The rack frame hosts redundant I/O module pairs connected via an integrated backplane bus, delivering hot-standby redundancy to ensure uninterrupted signal transmission during primary card failures. Operating across an ambient temperature envelope of -20 to +55 deg C, the 8.5 kg chassis provides electrical distribution and mechanical support for up to 8 input/output channels across safety-critical control loops.

Hardware Specifications

Parameter Specification
Model FC-IOCHAS-0003R
Brand Honeywell
Origin USA
Weight 8.5 kg
Dimensions 177 mm x 482.6 mm x 280 mm
Operating Temp -20 to +55 deg C
Humidity Range 5% to 95% RH (non-condensing)
Power Supply Voltage 24 VDC
Module Type Redundant I/O Chassis
Redundancy Architecture Hot Standby
Channel Capacity Supports 8 input/output channels
Input Signal Range 0-20 mA / 4-20 mA
Output Signal Range 0-20 mA / 4-20 mA
Bus Communication Modbus RTU protocol support
Certifications CE, TUV, UL508, CSA

Channel-to-Channel Isolation & 4-20 mA HART Loop Integration

The FC-IOCHAS-0003R incorporates backplane galvanic isolation barriers and noise suppression routing across all 8 I/O channel paths. The internal bus decoupling protects internal processor communication against field-side electrical surges, cross-talk, and ground loop potentials. Designed to support standard 0-20 mA and 4-20 mA current loops, the backplane maintains signal fidelity for digital process variables and 4-20 mA HART loop protocol telemetry, preventing transient faults on one branch from propagating to secondary redundant cards or primary controllers.

Frequently Asked Questions

Q: How does the hot-standby redundancy mechanism operate within the FC-IOCHAS-0003R frame?

A: The chassis backplane actively routes dual power and signal paths to primary and secondary I/O module slots, enabling immediate fault-over transfer without interrupting active control signals.

Q: What physical mounting standards apply to the FC-IOCHAS-0003R chassis assembly?

A: With overall dimensions of 177 mm x 482.6 mm x 280 mm, the enclosure aligns with standard 19-inch industrial rack cabinets using designated side-flange retention points.

Q: What compliance certifications govern the electrical safety of this chassis?

A: The chassis is certified under CE, TUV, UL508, and CSA standards for installation in industrial automation environments.

Field Installation Guidelines

  1. Mount the 8.5 kg chassis into a standard 19-inch enclosure frame, securing all four corner mounting flange bolts to structural cabinet rails.
  2. Connect dual 24 VDC feed wires to primary and secondary power terminals to establish redundant backplane power distribution.
  3. Route field I/O cabling through cable managers, keeping low-voltage 0-20 mA and 4-20 mA signal wires isolated from AC power lines.
  4. Attach all cable shields directly to the cabinet main ground bar using low-impedance grounding clamps to prevent noise interference.
  5. Verify that cabinet ambient temperature stays within -20 to +55 deg C and relative humidity remains below 95% non-condensing prior to energizing system loops.

Cómo obtener una cotización