FC-IOCHAS-0003R Honeywell Redundant I/O Chassis
Specifications
Manufacturer: Honeywell
Product No.: FC-IOCHAS-0003R
Condition: 10 Artículos en stock
Product Type: I/O Chassis
Product Origin: USA
Payment:T/T, Western Union
Weight: 8500g
Shipping port: Xiamen
Warranty: 12 months
Detalles de producto
Descripción
Configured for high-availability backplane routing and fault-tolerant signal execution in Honeywell Safety Manager platforms, the Honeywell FC-IOCHAS-0003R (FC-IOCHAS-0003R Redundant I/O Chassis) provides direct physical/electrical execution. The rack frame hosts redundant I/O module pairs connected via an integrated backplane bus, delivering hot-standby redundancy to ensure uninterrupted signal transmission during primary card failures. Operating across an ambient temperature envelope of -20 to +55 deg C, the 8.5 kg chassis provides electrical distribution and mechanical support for up to 8 input/output channels across safety-critical control loops.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FC-IOCHAS-0003R |
| Brand | Honeywell |
| Origin | USA |
| Weight | 8.5 kg |
| Dimensions | 177 mm x 482.6 mm x 280 mm |
| Operating Temp | -20 to +55 deg C |
| Humidity Range | 5% to 95% RH (non-condensing) |
| Power Supply Voltage | 24 VDC |
| Module Type | Redundant I/O Chassis |
| Redundancy Architecture | Hot Standby |
| Channel Capacity | Supports 8 input/output channels |
| Input Signal Range | 0-20 mA / 4-20 mA |
| Output Signal Range | 0-20 mA / 4-20 mA |
| Bus Communication | Modbus RTU protocol support |
| Certifications | CE, TUV, UL508, CSA |
Channel-to-Channel Isolation & 4-20 mA HART Loop Integration
The FC-IOCHAS-0003R incorporates backplane galvanic isolation barriers and noise suppression routing across all 8 I/O channel paths. The internal bus decoupling protects internal processor communication against field-side electrical surges, cross-talk, and ground loop potentials. Designed to support standard 0-20 mA and 4-20 mA current loops, the backplane maintains signal fidelity for digital process variables and 4-20 mA HART loop protocol telemetry, preventing transient faults on one branch from propagating to secondary redundant cards or primary controllers.
Frequently Asked Questions
Q: How does the hot-standby redundancy mechanism operate within the FC-IOCHAS-0003R frame?
A: The chassis backplane actively routes dual power and signal paths to primary and secondary I/O module slots, enabling immediate fault-over transfer without interrupting active control signals.
Q: What physical mounting standards apply to the FC-IOCHAS-0003R chassis assembly?
A: With overall dimensions of 177 mm x 482.6 mm x 280 mm, the enclosure aligns with standard 19-inch industrial rack cabinets using designated side-flange retention points.
Q: What compliance certifications govern the electrical safety of this chassis?
A: The chassis is certified under CE, TUV, UL508, and CSA standards for installation in industrial automation environments.
Field Installation Guidelines
- Mount the 8.5 kg chassis into a standard 19-inch enclosure frame, securing all four corner mounting flange bolts to structural cabinet rails.
- Connect dual 24 VDC feed wires to primary and secondary power terminals to establish redundant backplane power distribution.
- Route field I/O cabling through cable managers, keeping low-voltage 0-20 mA and 4-20 mA signal wires isolated from AC power lines.
- Attach all cable shields directly to the cabinet main ground bar using low-impedance grounding clamps to prevent noise interference.
- Verify that cabinet ambient temperature stays within -20 to +55 deg C and relative humidity remains below 95% non-condensing prior to energizing system loops.