{"product_id":"fc-term-0001-honeywell-safety-manager-bus-terminator","title":"FC-TERM-0001 | Honeywell | Safety Manager Bus Terminator","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TERM-0001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-TERM-0001\u003c\/strong\u003e Bus Terminator, operates as a dedicated hardware component for high-frequency signal reflection suppression and characteristic impedance matching within Safety Manager backplane communication networks. Mounted directly on the communication bus end nodes, the unit terminates signal lines to prevent data corruption and maintain electromagnetic balance across the chassis assembly. Operating as a passive termination network, it consumes minimal board power while maintaining bus voltage integrity across standard operational temperature limits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TERM-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 25.4 cm x 11.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (no external power draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eBus Terminator Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eDirect chassis \/ Backplane slot insertion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance Matching\u003c\/td\u003e\n\u003ctd\u003eStandard differential bus termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ FSC Chassis Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Signal Integrity \u0026amp; Channel Isolation Support\u003c\/h3\u003e\n\u003cp\u003eThe FC-TERM-0001 maintains balanced line termination to eliminate standing waves and signal attenuation across differential backplane traces. By maintaining target characteristic impedance, the termination resistor array preserves digital edge steepness for high-speed processor-to-I\/O communication. This impedance matching minimizes packet retransmission rates and protects sensitive channel-to-channel isolation circuits from ground bounce and voltage ringing caused by open-ended transmission lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the FC-TERM-0001 bus terminator require active power wiring?\u003c\/p\u003e\n\u003cp\u003eA: No, the FC-TERM-0001 functions as a passive resistive termination assembly and derives no external power from field terminal blocks or system supplies.\u003c\/p\u003e\n\u003cp\u003eQ: Where must the FC-TERM-0001 be physically installed in the rack system?\u003c\/p\u003e\n\u003cp\u003eA: The terminator must be installed at the final physical slot or end-node connector of the Safety Manager backplane bus sequence to close the transmission line correctly.\u003c\/p\u003e\n\u003cp\u003eQ: What happens to bus communication if the terminator is missing from the chassis?\u003c\/p\u003e\n\u003cp\u003eA: An unterminated bus causes high-frequency signal reflections along the backplane traces, resulting in noise, transmission frame errors, and temporary loss of I\/O communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the backplane slot interface for bent pins or debris prior to mounting the termination assembly.\u003c\/li\u003e\n\u003cli\u003eAlign the FC-TERM-0001 module with the designated physical end-slot guide rails on the Safety Manager chassis.\u003c\/li\u003e\n\u003cli\u003eSlide the module firmly into the connector until the backplane seating tabs fully lock into position.\u003c\/li\u003e\n\u003cli\u003eTighten the top and bottom retaining screws to ensure continuous chassis frame ground bonding.\u003c\/li\u003e\n\u003cli\u003eVerify that no open signal expansion ports remain unterminated before energizing the cabinet backplane power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52642677817640,"sku":"FC-TERM-0001","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FC-TERM-00012_Cocoai.png?v=1789982785","url":"https:\/\/www.powerdcs.com\/es\/products\/fc-term-0001-honeywell-safety-manager-bus-terminator","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}