{"product_id":"fc-tsdo-04uni-safety-manager-system-module-honeywell","title":"FC-TSDO-04UNI Safety Manager System Module | Honeywell","description":"\u003cp\u003eConfigured for high-current digital actuation in Safety Manager systems, the \u003cstrong\u003eHoneywell FC-TSDO-04UNI\u003c\/strong\u003e (\u003cstrong\u003eFC-TSDO-04UNI\u003c\/strong\u003e Safety Manager System Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TSDO-04UNI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eShipping Weight: 3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e60 x 70 x 54 mm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C (standard panel ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower consumption unlisted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSafety Manager System Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e50 VDC (IEC 1010 Overvoltage Category 3) \/ 150 VDC (IEC 1010 Overvoltage Category 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e2 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail Compatibility\u003c\/td\u003e\n\u003ctd\u003eDIN EN TS32 \/ TS35 x 7.5 (Used rail length: 61 mm \/ 2.40 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Specifications\u003c\/td\u003e\n\u003ctd\u003eScrew terminals: Max wire 2.5 mm2 (AWG 14), Strip length 7 mm (0.28 in), Torque 0.5 Nm (0.37 ft-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-integrity field device control, the module executes switching operations across 4 high-current output channels rated for up to 2 A continuous load each. Built-in channel-to-channel isolation and physical separation protect internal backplane electronics from field-side voltage transients, maintaining compliance with IEC 1010 overvoltage category standards up to 150 VDC. The isolated output channels prevent common-mode voltage transfer between load circuits, safeguarding overall Safety Manager loop control and system logic execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the strict overvoltage category limits for this output module?\u003c\/p\u003e\n\u003cp\u003eA: The module is rated for a maximum continuous operating voltage of 50 VDC under IEC 1010 Overvoltage Category 3 environments, and up to 150 VDC under IEC 1010 Overvoltage Category 2 field installations.\u003c\/p\u003e\n\u003cp\u003eQ: What are the torque and conductor sizing specifications for field wiring terminals?\u003c\/p\u003e\n\u003cp\u003eA: Screw terminals accept a maximum conductor size of 2.5 mm2 (AWG 14) with a wire strip length of 7 mm (0.28 in). All terminal screws must be tightened strictly to 0.5 Nm (0.37 ft-lb).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize all field loop power supplies before attaching or removing terminal wiring connections to prevent arc flash hazards.\u003c\/li\u003e\n\u003cli\u003eSnap the module base firmly onto standard DIN EN TS32 or TS35 x 7.5 mounting rails, ensuring a minimum dedicated rail length of 61 mm (2.40 in).\u003c\/li\u003e\n\u003cli\u003eStrip all field wires precisely to 7 mm (0.28 in) to ensure full contact engagement within the terminal block without leaving exposed bare copper.\u003c\/li\u003e\n\u003cli\u003eTorque all terminal screw connections to 0.5 Nm using a calibrated torque screwdriver to maintain gas-tight electrical contact and avoid stripping threads.\u003c\/li\u003e\n\u003cli\u003eRoute high-current DC output cabling in dedicated grounded conduits segregated from low-voltage sensitive analog signal lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52501607317800,"sku":"FC-TSDO-04UNI","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FC-TSDO-04UNI.jpg?v=1789890818","url":"https:\/\/www.powerdcs.com\/es\/products\/fc-tsdo-04uni-safety-manager-system-module-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}