FC-USI-0002 CC V2.0 | Honeywell | Universal System Interface Module

Specifications

  • Manufacturer: Honeywell

  • Product No.: FC-USI-0002 CC V2.0

  • Condition: 10 Artículos en stock

  • Product Type: Safety Interface Modules

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 800g

  • Shipping port: Xiamen

  • Warranty: 12 months

Detalles de producto

Descripción

Configured for high-speed network communication and serial interface processing in Honeywell Safety Manager platforms, the Honeywell FC-USI-0002 CC V2.0 (FC-USI-0002 Universal System Interface Module) provides direct physical/electrical execution. Driven by an integrated communication processor backed by 8 MB Flash memory and 8 MB local SRAM with Error Detection and Correction (EDAC), the card routes telemetry across dual 10/100 Mbps Ethernet ports and two configurable serial channels. The assembly provides real-time data buffer exchange via 256 KB shared RAM to execute deterministic safety system control protocols.

Suffix Breakdown & Model Matrix

Model Number Revision / Coating Communication Ports Operating Temperature
FC-USI-0002 CC V2.0 Conformal Coated (CC), Rev V2.0 2x Ethernet, 2x Serial (RS-232/485) -20 to +50 deg C
FC-USI-0002 CC V1.0 Conformal Coated (CC), Rev V1.0 2x Ethernet, 2x Serial (RS-232/485) -20 to +50 deg C

Hardware Specifications

Parameter Specification
Model FC-USI-0002 CC V2.0
Brand Honeywell
Origin USA
Weight 0.8 kg
Dimensions 105 mm x 105 mm x 29 mm
Operating Temp -20 to +50 deg C
Power Consumption Max 1.2 A at 24 VDC / 5 VDC +/-5%
Ethernet Ports 2 ports (10/100 Mbps)
Serial Channels 2 channels (RS-232 / RS-485)
Flash Memory 8 MB
Local SRAM 8 MB with EDAC
Shared RAM 256 KB

Channel-to-Channel Isolation & Protocol Management

The FC-USI-0002 CC V2.0 features dual isolated serial channels (RS-232/RS-485) and dual 10/100 Mbps Ethernet ports engineered for high-availability process control networks. Integrated channel-to-channel isolation and galvanic shielding protect internal 256 KB Shared RAM buffers from field-side ground loops and surge transients. Compatible with 4-20 mA HART loop protocol gateways and DCS controllers, the unit preserves high-speed backplane data integrity without compromising safety processor determinism.

Frequently Asked Questions

Q: What is the primary difference between revision V2.0 and earlier hardware revisions of the FC-USI-0002 CC?

A: Revision V2.0 incorporates updated internal bus components and firmware flash compatibility enhancements while maintaining identical physical dimensions, power pinouts, and backplane slot compliance.

Q: How does the local memory error handling operate during active system operation?

A: The 8 MB local SRAM features built-in Error Detection and Correction (EDAC) hardware logic that automatically identifies and rectifies single-bit memory faults in real time.

Field Installation Guidelines

  1. Isolate all rack primary power feeds prior to inserting or removing the FC-USI-0002 CC V2.0 module from its backplane slot.
  2. Verify that serial communication links (RS-232/RS-485) utilize shielded twisted-pair cables with drain wires terminated to a single earth ground bar.
  3. Secure RJ45 network cabling using mechanical connector latches to prevent intermittent Ethernet communication drops.