FS-PDC-CPSET Honeywell Power Distribution Cable Set

Specifications

  • Manufacturer: Honeywell

  • Product No.: FS-PDC-CPSET

  • Condition: 10 Artículos en stock

  • Product Type: Power Cable Sets

  • Payment:T/T, Western Union

  • Weight: 5000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Detalles de producto

Descripción

The Honeywell FS-PDC-CPSET, also cataloged as the FS-PDC-CPSET Power Distribution Cable Set, operates as a dedicated hardware component for 24 Vdc power delivery to Control Processors within Honeywell Safety Manager platforms.

Hardware Specifications

Parameter Specification
Model FS-PDC-CPSET
Brand Honeywell
Origin USA
Weight 5.00 kg (shipping weight)
Dimensions Cable 1: 54 cm (21.26 in) / Cable 2: 77 cm (30.31 in)
Operating Temp -20 deg C to +70 deg C
Power Consumption Passive conductor assembly (24 Vdc rated)
Cable Specification CC600 2 x 2.5 mm2 conductors
Set Composition 2 power cables (1 set per Control Processor assembly)
Bus Bar Termination 2-pole Squeeze-To-Release type (D-TAB-200-STR)
Controller Termination 2-pole Mate-N-Lok connector assembly

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The FS-PDC-CPSET utilizes heavy-duty CC600 double-insulated 2.5 mm2 conductors to minimize DC voltage drops across high-current supply paths. High-integrity shielding and physical segregation of the dual 24 Vdc supply lines mitigate low-frequency power ripple and switching noise from backplane buses. This structural isolation prevents ground loops and preserves the channel-to-channel isolation parameters essential for processing low-level field signals executing 4-20 mA HART loop protocol telemetry across adjacent I/O racks.

Frequently Asked Questions

Q: What are the distinct connector types used on the bus bar and controller ends of the FS-PDC-CPSET assembly?

A: The bus bar termination uses a 2-pole D-TAB-200-STR Squeeze-To-Release connector, while the Safety Manager controller interface utilizes a 2-pole Mate-N-Lok connector.

Q: How are the individual cable lengths differentiated within the FS-PDC-CPSET cable pair?

A: The set includes two cables with specific lengths: FS-PDC-CP24-1 measures 54 cm (21.26 in) and FS-PDC-CP24-2 measures 77 cm (30.31 in) to accommodate dual redundant power bus positioning.

Q: Does servicing a single cable in the FS-PDC-CPSET require powering down the entire controller rack?

A: Under redundant power supply architectures, individual power cables can be disconnected sequentially via their quick-release connectors without disturbing the active redundant power feed.

Field Installation Guidelines

  • Ensure the 24 Vdc primary power feed is de-energized prior to mating or unmating the D-TAB-200-STR bus bar connectors.

  • Verify positive engagement of the Mate-N-Lok retention tabs on the controller side to avoid intermittent contact under vibration.

  • Maintain adequate cable routing bend radii to prevent conductor tension and sleeve degradation along cabinet channels.

  • Connect all protective earth and shield drain conductors to the cabinet ground bus prior to restoring system power.