FS-PDC-MB24-1 Honeywell Power Distribution Cable
Specifications
Manufacturer: Honeywell
Product No.: FS-PDC-MB24-1
Condition: 10 Artículos en stock
Product Type: Power Distribution Cables
Payment:T/T, Western Union
Weight: 320g
Shipping port: Xiamen
Warranty: 12 months
Detalles de producto
Descripción
The Honeywell FS-PDC-MB24-1, also cataloged as the FS-PDC-MB24-1 Power Distribution Cable, operates as a dedicated hardware component for 24 VDC power transfer from the MB-0001 mains rail to the PDB-0824 power distribution board within Honeywell Safety Manager platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FS-PDC-MB24-1 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.71 lbs (0.32 kg) |
| Dimensions | 145 cm length |
| Operating Temp | 0 deg C to +60 deg C |
| Power Consumption | Passive distribution assembly (Zero internal power draw) |
| Voltage Rating | 24 VDC |
| Source Connection | MB-0001 Mains Power Rail |
| Destination Connection | PDB-0824 Power Distribution Board |
| Cable Type | Power Distribution Cable |
| System Compatibility | Honeywell Safety Manager / FSC Systems |
4-20 mA HART Loop Protocol and Channel-to-Channel Isolation
The power cable assembly incorporates heavy-duty insulation barriers and low-resistance copper conductors to deliver stable 24 VDC operating power to downstream distribution boards. High-dielectric conductor insulation maintains physical channel-to-channel isolation between auxiliary power lines and neighboring signal conductors. This electrical separation prevents DC bus switching transients and ground potential differences from coupling into 4-20 mA HART loop protocol circuits or discrete safety I/O channels operating in the same enclosure.
Frequently Asked Questions
Q: What specific hardware modules are interconnected by the FS-PDC-MB24-1 cable?
A: The cable directly routes 24 VDC power from an MB-0001 mains power rail to a PDB-0824 power distribution board inside Safety Manager cabinets.
Q: Is live disconnection of the FS-PDC-MB24-1 cable assembly permitted during system operation?
A: No, field 24 VDC power feeding the cable must be isolated prior to disconnection to prevent electrical arcing on pin headers and unpowered dropouts on connected I/O sub-assemblies.
Q: How does the cable construction protect against noise coupling to signal wiring?
A: Thick PVC outer jacket insulation and tight conductor twisting isolate the 24 VDC power feed from inductive cross-talk with parallel field signal cables.
Field Installation Guidelines
- De-energize the MB-0001 power source prior to connecting or removing the cable assembly.
- Route the 145 cm cable through dedicated DC power wireways inside the cabinet, keeping it separate from high-voltage AC feeds.
- Align the connector plugs squarely with mating header sockets on the MB-0001 rail and PDB-0824 board until retention latches engage fully.
- Verify that cabinet protective earth (PE) grounding is secure before restoring 24 VDC power to the system.