FS-TSRO-0824 Honeywell Digital Output Field Termination Assembly

Specifications

  • Manufacturer: Honeywell

  • Product No.: FS-TSRO-0824

  • Condition: 10 Artículos en stock

  • Product Type: Digital Output Modules

  • Payment:T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Detalles de producto

Descripción

Configured for discrete relay output switching and high-current load execution in Honeywell Safety Manager systems, the Honeywell FS-TSRO-0824 (FS-TSRO-0824 Digital Output Field Termination Assembly) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model FS-TSRO-0824
Brand Honeywell
Origin USA
Weight 2.00 kg (Shipping weight)
Dimensions 300 mm x 70 mm x 60 mm (L x W x H)
Operating Temp -20 deg C to +60 deg C
Power Consumption Typically 40 mA at 24 VDC per energized relay coil
Channels 8 relay output channels
Nominal Input Voltage 24 VDC (36 VDC max. input voltage)
Relay Pick-Up Voltage 19.2 VDC
Max Switched Voltage 250 VAC / 250 VDC
Max Switched Current 5 A per channel (fused)
Min Switched Current 1 mA at 5 VDC
Max Switched Power 1250 VA / 150 W
Safety Classification AK1-6 (TUV, CE, UL pending)

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The field termination module incorporates galvanic isolation barriers between the 24 VDC control side relay coils and output contacts, maintaining strict channel-to-channel isolation across all 8 switching channels. Physical isolation prevents high-voltage AC switching transients and inductive kickback on field output lines from coupling into sensitive 4-20 mA HART loop protocol analog input signals or backplane logic buses operating within adjacent chassis racks.

Frequently Asked Questions

Q: What protection is provided for individual output switching channels on the FS-TSRO-0824?

A: Each of the 8 output channels features an integrated 5 A fuse to protect relay contacts and field wiring from overcurrent conditions.

Q: What is the minimum activation threshold required for reliable relay coil energization?

A: The relay pick-up voltage is specified at 19.2 VDC, below which the relay contacts will remain in their de-energized shelf state.

Q: Can the FS-TSRO-0824 switch both AC and DC field loads?

A: Yes, the dry relay contacts support switching up to 250 VAC (1250 VA max) or 250 VDC (150 W max) per channel.

Field Installation Guidelines

  • Mount the assembly on standard DIN rails within the control cabinet, ensuring vertical orientation to facilitate free convection cooling.
  • Verify that field output load currents do not exceed the 5 A continuous channel rating prior to connecting field field wiring terminals.
  • Connect inductive AC or DC loads with parallel suppressor elements (RC networks or flyback diodes) across field field contacts to suppress arc discharge and extend contact lifecycle.
  • Maintain separate wire channels for 24 VDC control cables and high-voltage 250 VAC output wiring to prevent cross-talk and electromagnetic induction.