{"product_id":"honeywell-51304465-300-cable-assembly","title":"Honeywell 51304465-300 Cable Assembly","description":"\u003cp\u003eThe Honeywell \u003cstrong\u003e51304465-300\u003c\/strong\u003e is a shielded twisted-pair cable assembly engineered for high-speed signal integrity and inter-rack communication within TDC 3000 and Experion PKS DCS architectures. It provides reliable physical and electrical interconnection for control system loops and data links in industrial environments.\u003c\/p\u003e\n\u003ch3\u003eSignal Integrity and Shielding Design\u003c\/h3\u003e\n\u003cp\u003eThe cable assembly incorporates heavy-duty foil and braided shielding to suppress common-mode noise, electromagnetic interference (EMI), and radio frequency interference (RFI). Its twisted-pair geometry and physical insulation barrier prevent signal cross-talk and ground loops from degrading 4-20 mA HART loop protocol telemetry or digital backplane communications between connected hardware units.\u003c\/p\u003e\n\u003ch3\u003eMechanical and Environmental Parameters\u003c\/h3\u003e\n\u003cp\u003eBuilt for industrial control cabinet installations, the unit operates across a temperature range of 0 deg C to +70 deg C. It is equipped with multi-pin heavy-duty interface connectors for secure physical engagement and features an approximate weight of 0.8 kg.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304465-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive interconnect cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded twisted-pair interconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 \/ Experion PKS DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMulti-pin heavy-duty interface connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eField Installation Guidelines\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the cable through designated cabinet wiring channels, keeping low-voltage signal lines isolated from high-voltage AC distribution circuits.\u003c\/li\u003e\n\u003cli\u003eSecurely tighten all connector thumbscrews and latching mechanisms to ensure low-resistance pin contact and strain relief.\u003c\/li\u003e\n\u003cli\u003eEnsure the drain wire and cable shield bond directly to the cabinet protective earth (PE) grounding bar at one end only to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003eMaintain specified minimum bend radius constraints along the cable run to avoid internal wire fatigue or shielding degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary application of the 51304465-300 cable?\u003c\/p\u003e\n\u003cp\u003eA: It functions as a shielded twisted-pair interconnect assembly for connecting I\/O racks, Field Termination Assemblies (FTAs), or processor modules within Honeywell DCS cabinets.\u003c\/p\u003e\n\u003cp\u003eQ: How does the cable construction mitigate electrical noise in industrial environments?\u003c\/p\u003e\n\u003cp\u003eA: High-density braid and foil shielding along with twisted-pair geometry eliminate cross-talk between channels and prevent external EMI\/RFI noise pickup.\u003c\/p\u003e\n\u003cp\u003eQ: Does installing or replacing this cable require disconnecting power to the associated I\/O rack?\u003c\/p\u003e\n\u003cp\u003eA: System power or associated loop breakers should be isolated per Honeywell maintenance guidelines prior to disconnecting the cable to prevent signal spikes or communication interrupts.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68098220818728,"sku":"51304465-300","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/MU-KFTA1051201420-010_8fc5386b-d8ea-49ba-b644-b452854834c9.jpg?v=1793781973","url":"https:\/\/www.powerdcs.com\/es\/products\/honeywell-51304465-300-cable-assembly","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}