Honeywell 51309218-125 Low Level Analog Module
Specifications
Manufacturer: Honeywell
Product No.: 51309218-125
Condition: 10 Artículos en stock
Product Type: Termination Boards
Product Origin: USA
Payment:T/T, Western Union
Weight: 5000g
Shipping port: Xiamen
Warranty: 12 months
Detalles de producto
Descripción
Configured for low-level RTD analog input multiplexing and field temperature signal termination in Honeywell TDC 3000 and Experion PKS systems, the Honeywell 51309218-125, also cataloged as the 51309218-125 Low Level Analog Input Multiplexer RTD FTA, provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 51309218-125 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 5.0 kg (Shipping) |
| Operating Temp | -10 to +55 deg C |
| Power Consumption | Passive field interface load |
| Input Channels | 16 channels |
| Sensor Interface | RTD (Resistance Temperature Detector) |
| Terminal Type | Compression terminals |
| IOP Interface | Single IOP interface (Redundancy not supported) |
| Compliance | Not CE compliant, not conformally coated |
Cold Junction Compensation & Channel Isolation
The low-level multiplexer termination assembly interface conditions millivolt-level resistance changes across 16 dedicated RTD sensor input loops before passing digitized values to the primary I/O processor card. High-density channel isolation and filtering circuits attenuate common-mode electromagnetic noise and stray ground currents on field cabling, preventing signal drift. This low-level signal conditioning maintains measurement precision for temperature process loops running alongside standard 4-20 mA HART loop protocol analog channels within shared control cabinets.
Frequently Asked Questions
Q: Does the 51309218-125 FTA assembly support redundant I/O processor (IOP) topologies?
A: No, the 51309218-125 is engineered exclusively for a single IOP interface configuration; dual redundant IOP connections are not supported.
Q: What environmental coating and compliance specifications apply to this part number?
A: Part number 51309218-125 is non-CE compliant and is supplied without conformal coating.
Q: What type of field wiring termination hardware is integrated on the board?
A: Field conductor connections are established directly via onboard compression terminal blocks.
Field Installation Guidelines
- Disconnect backplane power and field instrument loop power before installing or removing the FTA board from the mounting channel.
- Fasten the assembly onto the standard enclosure rail using designated retention hardware to ensure mechanical stability.
- Wire incoming 2-wire, 3-wire, or 4-wire RTD sensor leads to the corresponding compression terminals, ensuring screws are torqued to spec.
- Route low-level RTD signal conductors in separate grounded metallic conduits away from high-voltage AC cables and switching inductive loads.
- Ground all individual cable shield drain wires at the single-point cabinet enclosure earth bar to minimize noise interference on millivolt inputs.