{"product_id":"honeywell-8c-ip0101-51454362-175-profibus-gateway-assembly","title":"Honeywell 8C-IP0101 51454362-175 PROFIBUS Gateway Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-IP0101 51454362-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8C-IP0101 51454362-175\u003c\/strong\u003e PROFIBUS Gateway Assembly, operates as a dedicated hardware component for fieldbus communication and protocol translation within Honeywell Experion PKS control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-IP0101 51454362-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 100 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eUnspecified (24 VDC nominal supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454362-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Coating\u003c\/td\u003e\n\u003ctd\u003eConformal coated for environmental protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFieldbus Integration \u0026amp; Process Control Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 8C-IP0101 51454362-175 gateway assembly connects high-speed PROFIBUS DP field networks directly into Series C I\/O communication structures. Featuring factory conformal coating, the module resists harsh industrial environmental contamination, humidity, and atmospheric oxidation. Built-in channel-to-channel isolation protects central DCS logic from field loops, while internal protocol execution engine components process real-time 4-20 mA HART loop protocol parameters and PROFIBUS field device diagnostics without communication packet delay.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What environmental protection is implemented on the 8C-IP0101 51454362-175 assembly?\u003c\/p\u003e\n\u003cp\u003eA: The 8C-IP0101 51454362-175 features factory conformal coating on internal circuit boards to withstand aggressive industrial air conditions across a -40 to 70 deg C operating thermal range.\u003c\/p\u003e\n\u003cp\u003eQ: What power voltage input does the 8C-IP0101 51454362-175 require for operation?\u003c\/p\u003e\n\u003cp\u003eA: The assembly requires a regulated 24 VDC input voltage connected to designated power distribution terminals.\u003c\/p\u003e\n\u003cp\u003eQ: How is the 8C-IP0101 51454362-175 physically installed inside a cabinet?\u003c\/p\u003e\n\u003cp\u003eA: The module attaches directly to standard 35 mm DIN rail tracks using integrated rear retention mounting brackets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation\u003c\/strong\u003e: Hook the top slot of the 8C-IP0101 51454362-175 onto the 35 mm DIN rail, then snap the lower spring clip into place until locked.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection\u003c\/strong\u003e: Connect 24 VDC supply leads with correct electrical polarity to prevent input circuit trip conditions before powering the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield \u0026amp; Noise Mitigation\u003c\/strong\u003e: Clamp PROFIBUS DP cable shielding directly to cabinet grounding bars using low-impedance grounding connections to suppress high-frequency noise interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52312822448424,"sku":"8C-IP0101 51454362-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/8C-PAON01.jpg?v=1788250557","url":"https:\/\/www.powerdcs.com\/es\/products\/honeywell-8c-ip0101-51454362-175-profibus-gateway-assembly","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}