{"product_id":"honeywell-cc-pain01-51410069-175-experion-c300-analog-input-module","title":"Honeywell CC-PAIN01 51410069-175 Experion C300 Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIN01 51410069-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-PAIN01\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for high-level current signal acquisition within Honeywell C300 control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAIN01 51410069-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 lbs (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.0 in x 2.4 in x 0.8 in (152.4 mm x 61.0 mm x 20.3 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNon-incendive field power execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51410069-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent (4-20 mA, 2-wire or self-powered transmitters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e70 dB (DC to 60 Hz, 500 ohm imbalance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell C300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAIN01 51410069-175 high-level analog input module acquires current signals directly from 2-wire or self-powered field transmitters. Operating across standard 4-20 mA HART loop protocol architectures, the internal circuitry enforces robust common mode rejection of 70 dB (DC to 60 Hz with a 500 ohm imbalance). This maintains signal integrity and provides channel-to-channel isolation against line transients and ground loops before digital data is routed over the backplane bus to the main controller.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-PAIN01 module provide power to 2-wire field transmitters directly from its terminals?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module interface supplies non-incendive power rails designed to energize standard 2-wire 4-20 mA current loops, while also accommodating external self-powered loops.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CC-PAIN01 module be hot-swapped during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports plug-in removal and insertion on an active IOTA base without disrupting backplane communications or requiring a C300 controller reboot.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the corresponding C300 IOTA base assembly onto the panel chassis or DIN rail before seating the module.\u003c\/li\u003e\n\u003cli\u003eAlign the backplane connector pins of the CC-PAIN01 module with the target slot on the IOTA and press firmly until mechanical latches click into place.\u003c\/li\u003e\n\u003cli\u003eTerminate 4-20 mA field loops on the designated IOTA screw terminals, paying strict attention to loop power polarity for 2-wire and self-powered field devices.\u003c\/li\u003e\n\u003cli\u003eRoute low-voltage analog signal cables in separate wiring troughs at a distance of at least 200 mm from high-voltage AC conductors.\u003c\/li\u003e\n\u003cli\u003eConnect cable shield drain wires to a single-point cabinet ground bus bar to suppress high-frequency noise and ground loop currents.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52357307040040,"sku":"CC-PAIN01 51410069-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-PAIH0251405038-3751_97c35c4d-5e33-4a18-8866-218c54f77e66.png?v=1788939448","url":"https:\/\/www.powerdcs.com\/es\/products\/honeywell-cc-pain01-51410069-175-experion-c300-analog-input-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}