{"product_id":"honeywell-cc-tdod51-experion-pks-series-c-digital-output-module","title":"Honeywell CC-TDOD51 Experion PKS Series-C Digital Output Module","description":"\u003cp\u003eConfigured for discrete load switching in Experion PKS Series-C control systems, the \u003cstrong\u003eHoneywell CC-TDOD51\u003c\/strong\u003e (\u003cstrong\u003eCC-TDOD51\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. It handles 32 open-drain sinking output channels across Input\/Output Termination Assembly (IOTA) backplane networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TDOD51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e263 mm x 58 mm x 28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32 discrete outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSink (Open Drain)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per channel (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eIntegrated short-circuit and over-voltage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eIOTA (Input\/Output Termination Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Digital Load Management\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TDOD51 digital output module executes switching logic for up to 32 independent sinking channels rated at 30 VDC and 0.1 A per point. Integrated protection circuits safeguard field connections against short-circuit and over-voltage conditions, maintaining signal integrity across the backplane bus. The module interacts with field instrumentation loop architectures using software-configurable output parameters while isolating internal DCS logic from field-side voltage spikes and electrical transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CC-TDOD51 digital output channels drive loads exceeding 0.1 A individually?\u003c\/p\u003e\n\u003cp\u003eA: No, the maximum current rating is strictly 0.1 A per channel at 30 VDC. Exceeding this limit triggers internal short-circuit protection to protect channel circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: Is the CC-TDOD51 supported for live replacement on an energized IOTA base?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports plug-in hot-swap capability on an active IOTA base without de-energizing adjacent system components or interrupting backplane communications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the IOTA base securely onto the cabinet DIN rail prior to module insertion.\u003c\/li\u003e\n\u003cli\u003eAlign the CC-TDOD51 module connectors with the IOTA slot and push firmly until the latches lock into position.\u003c\/li\u003e\n\u003cli\u003eVerify that load voltage supplies do not exceed the 30 VDC limit for the open-drain sinking outputs.\u003c\/li\u003e\n\u003cli\u003eRoute field digital output cabling through dedicated raceways physically separated from AC high-voltage lines by at least 200 mm to prevent noise coupling.\u003c\/li\u003e\n\u003cli\u003eConnect field cable shields to a dedicated cabinet grounding bar to ensure effective grounding and noise suppression.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52357181243688,"sku":"CC-TDOD51","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-TDOD51-removebg-preview.png?v=1788938697","url":"https:\/\/www.powerdcs.com\/es\/products\/honeywell-cc-tdod51-experion-pks-series-c-digital-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}