{"product_id":"honeywell-cc-udir01-experion-pks-c300-digital-input-relay-module","title":"Honeywell CC-UDIR01 Experion PKS C300 Digital Input Relay Module","description":"\u003cp\u003eConfigured for high-density digital contact state monitoring and isolated loop sensing in Experion PKS C300 systems, the \u003cstrong\u003eHoneywell CC-UDIR01\u003c\/strong\u003e (\u003cstrong\u003eCC-UDIR01\u003c\/strong\u003e Digital Input Relay Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-UDIR01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C300 I\/O Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003eDiscrete contact state detection channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eExperion PKS C300 IOTA Baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Digital Telemetry Execution\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-UDIR01 processes discrete contact closures and relay status feedback from field instrumentation across industrial plant networks. Incorporating dedicated optocouplers and galvanic channel-to-channel isolation barriers, the internal processing logic prevents common-mode voltage spikes, ground potential differentials, and severe field noise from propagating into the core C300 controller backplane. The module continuously samples input state changes with low conversion latency, delivering deterministic real-time digital status feedback to C300 control execution environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the CC-UDIR01 module hot-swappable on an active C300 IOTA baseplate?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CC-UDIR01 supports online insertion and removal (hot-swapping) on an energized C300 IOTA assembly without disrupting backplane bus communication or triggering controller faults.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-channel isolation protect the C300 controller backplane on the CC-UDIR01?\u003c\/p\u003e\n\u003cp\u003eA: Integrated optical and galvanic barriers isolate field-side discrete loop voltages from the internal backplane logic, suppressing electrical transients and preventing ground loops.\u003c\/p\u003e\n\u003cp\u003eQ: How are discrete channel states indicated on the physical module hardware?\u003c\/p\u003e\n\u003cp\u003eA: Front-panel LED status indicators display real-time channel state status, power rail health, and active module communication status for fast field diagnosis.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign the module rear backplane connectors with the target slot on the C300 IOTA baseplate and press firmly until the mechanical locking latches fully engage.\u003c\/li\u003e\n\u003cli\u003eRoute discrete input field wiring through dedicated wire channels, maintaining at least 200 mm clearance from high-voltage AC conductors to minimize inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003eTerminate signal cable shield drain wires at a single point on the cabinet earthing bar to prevent ground loop currents.\u003c\/li\u003e\n\u003cli\u003eVerify field contact voltage levels and field loop polarity before energizing the module channel power rails.\u003c\/li\u003e\n\u003cli\u003eProvide a minimum vertical clearance zone of 100 mm above and below the module assembly to allow adequate natural thermal convection airflow.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52357533958440,"sku":"CC-UDIR01","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-UDIR01_Cocoai.png?v=1788943467","url":"https:\/\/www.powerdcs.com\/es\/products\/honeywell-cc-udir01-experion-pks-c300-digital-input-relay-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}