{"product_id":"honeywell-fc-tdol-0724-digital-output-module","title":"Honeywell FC-TDOL-0724 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TDOL-0724\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-TDOL-0724\u003c\/strong\u003e Digital Output Field Terminal Assembly, operates as a dedicated hardware component for discrete driving output execution and real-time loop monitoring within Honeywell Safety Manager platforms. It delivers controlled switching signals across 7 digital output channels to actuate relays, valves, and field-side solenoids.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TDOL-0724\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e24 x 10.8 x 8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC external loop supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e7 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Monitoring\u003c\/td\u003e\n\u003ctd\u003eContinuous circuit integrity detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Signal Processing Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe FC-TDOL-0724 assembly integrates channel-to-channel isolation and galvanic separation barriers to protect logic solver backplanes against field-side electrical surges. Designed to operate alongside 4-20 mA HART loop protocol instruments in hybrid control cabinets, the module incorporates active filtering to isolate high-frequency noise. Integrated current-limiting circuitry and continuous loop integrity monitoring protect upstream controller buses from short-circuit faults or line breaks on individual field output runs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the continuous output current limit per channel on the FC-TDOL-0724?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 7 digital output channels supports a maximum continuous current load rating of 2 A at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle real-time wiring fault detection on field loops?\u003c\/p\u003e\n\u003cp\u003eA: Onboard continuous loop monitoring circuits actively measure field loop impedance, detecting open circuits or line faults when output channels are energized or de-energized.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported on the FC-TDOL-0724 terminal assembly?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is permitted provided field load circuits are isolated or power supply states are verified, preventing inductive arc transients during terminal extraction.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Mount the assembly inside an IP54 or better enclosure using standard mounting guides. Secure the housing to prevent movement caused by field vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring \u0026amp; Termination:\u003c\/strong\u003e Terminate discrete output lines and 24 VDC power conductors to the assigned screw terminal blocks. Observe strict polarity alignment for all channel loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Connect field cable drain wires to the main cabinet earth bus bar using single-point grounding clamps to minimize high-frequency noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route 24 VDC discrete output lines in separate wire ducts away from high-voltage AC lines, keeping a minimum physical separation distance of 30 cm.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52719757295912,"sku":"FC-TDOL-0724","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FC-TDOL-0724P_Cocoai_c3bb1b7d-aac2-4a7d-befc-6c9c1c098b0b.png?v=1790066201","url":"https:\/\/www.powerdcs.com\/es\/products\/honeywell-fc-tdol-0724-digital-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}