Honeywell FS-BKM-0001 Battery and Key Switch Module
Specifications
Manufacturer: Honeywell
Product No.: FS-BKM-0001
Condition: 10 Artículos en stock
Product Type: Battery & Key Switch Modules
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Detalles de producto
Descripción
The Honeywell FS-BKM-0001, also cataloged as the FS-BKM-0001 Battery and Key Switch Module, operates as a dedicated hardware component for system mode override, key-locked security execution, and backup battery power routing within Honeywell Safety Manager platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FS-BKM-0001 |
| Brand | Honeywell |
| Origin | USA |
| Weight | Approx. 0.50 kg |
| Dimensions | Standard Safety Manager chassis slot dimensions |
| Operating Temp | -40 deg C to +70 deg C |
| Power Consumption | Max. 20 mA @ 24 VDC (7 mA typ.), Max. 10 mA @ 5 VDC |
| Key Switch Type | SPST (Single Pole Single Throw) |
| Rated Voltage | 12 VDC nominal (14-31 VDC output supply range) |
| Supply Voltage Inputs | 24 VDC (+15% to +30%) and 5 VDC (+/-10%) |
| Output Resistance | Approx. 2 x 1.1 kohm (parallel) |
| Protection Rating | IP67 environmental protection rating |
4-20 mA HART Loop Protocol and Channel-to-Channel Isolation
The module incorporates galvanically decoupled key switch contacts and isolated battery backup lines to maintain strict channel-to-channel isolation across internal system buses. High-impedance switching circuits (approx. 2 x 1.1 kohm output resistance in parallel) prevent high-voltage noise coupling into adjacent logic solver backplane lines. This isolation architecture prevents transient voltage surges on the 24 VDC auxiliary power rail from interfering with process control signals or 4-20 mA HART loop protocol instruments connected to adjacent safety I/O modules.
Frequently Asked Questions
Q: What key switch mechanism and electrical contact configuration are integrated into the FS-BKM-0001?
A: The module uses an SPST (Single Pole Single Throw) mechanical key switch rated for low-current control signal switching and hardware access control.
Q: What are the primary DC input power requirements for module operation?
A: The module requires dual supply inputs consisting of a 24 VDC line (18.4 VDC to 31.2 VDC range, 20 mA maximum current draw) and a 5 VDC bus line (+/-10%, 10 mA maximum current draw).
Q: Can the backup battery circuit be serviced while the primary 24 VDC power supply remains energized?
A: Yes, battery removal can be executed without disrupting 5 VDC logic backplane power, provided proper grounding and anti-static ESD procedures are observed during handling.
Field Installation Guidelines
- Isolate auxiliary power lines connected to the module rack location prior to inserting or removing the unit.
- Align the module card-edge connectors with the designated chassis rails and slide in smoothly until backplane headers seat completely.
- Tighten front panel retaining screws to secure mechanical grounding against the rack frame and ensure IP67 front face sealing.
- Connect backup battery wiring directly to designated isolated terminals, ensuring correct polarity alignment before restoring primary 24 VDC system power.