Honeywell FS-CCE-232-02/L10 Communication Cable
Specifications
Manufacturer: Honeywell
Product No.: FS-CCE-232-02/L10
Condition: 10 Artículos en stock
Product Type: Communication Cables
Payment:T/T, Western Union
Weight: 1100g
Shipping port: Xiamen
Warranty: 12 months
Detalles de producto
Descripción
The Honeywell FS-CCE-232-02/L10, also cataloged as the FS-CCE-232-02/L10 Communication Cable, operates as a dedicated hardware component for RS-232 serial data transmission within Honeywell Safety Manager systems.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FS-CCE-232-02/L10 |
| Brand | Honeywell |
| Origin | USA |
| Weight | Approx. 1.10 kg |
| Dimensions | 10.0 m (32.8 ft) cable length |
| Operating Temp | -20 deg C to +70 deg C |
| Power Consumption | Passive signal transmission assembly |
| Interface Standard | RS-232 serial communication |
| Cable Length | 10.0 m |
| Conductor Type | Shielded multi-core twisted copper pairs |
| Connector Type | Industrial sub-D / module plug connectors |
| System Compatibility | Honeywell Safety Manager / FSC Controllers |
4-20 mA HART Loop Protocol and Channel-to-Channel Isolation
The FS-CCE-232-02/L10 cable utilizes high-coverage braided metallic shielding and foil wrapping to isolate high-speed serial data lines from external electromagnetic interference (EMI). By preventing serial switching noise from radiating onto adjacent cabinet backplanes, the cable protects the integrity of nearby analog I/O circuits. This preserves channel-to-channel isolation references and prevents signal distortion on field-side loops running 4-20 mA HART loop protocol communications.
Frequently Asked Questions
Q: What does the "L10" suffix represent in the FS-CCE-232-02/L10 part number?
A: The "L10" suffix designates the factory-manufactured overall cable length of 10.0 meters (32.8 ft).
Q: Is the FS-CCE-232-02/L10 cable designed for full-duplex RS-232 communication?
A: Yes, the cable incorporates dedicated transmit (TX), receive (RX), and handshake lines wired for standard full-duplex serial interface protocols.
Q: Can this communication cable be installed in the same wire duct as 230 VAC power lines?
A: No, low-voltage communication cabling must be physically separated from high-voltage AC cables to prevent inductive noise coupling and signal degradation.
Field Installation Guidelines
- Verify that controller serial ports are powered down or isolated before seating or removing the cable connectors.
- Tighten all connector thumbscrews and locking latches to ensure constant grounding contact and strain relief.
- Maintain a minimum bend radius of at least 10 times the cable outer diameter during wire duct installation.
- Connect shield drain wires directly to the designated enclosure earth bus bar at a single terminal point to prevent ground loops.