Honeywell FS-SICC-0001/L8 System Interconnection Cable

Specifications

  • Manufacturer: Honeywell

  • Product No.: FS-SICC-0001/L8

  • Condition: 10 Artículos en stock

  • Product Type: Cable Assemblies

  • Payment:T/T, Western Union

  • Weight: 350g

  • Shipping port: Xiamen

  • Warranty: 12 months

Detalles de producto

Descripción

The Honeywell FS-SICC-0001/L8, also cataloged as the FS-SICC-0001 System Interconnection Cable, operates as a dedicated hardware component for multi-core signal routing and field termination assembly (FTA) interconnection within Honeywell Safety Manager and FSC systems.

Hardware Specifications

Parameter Specification
Model FS-SICC-0001/L8
Brand Honeywell
Origin USA
Weight 0.35 kg
Dimensions 8 m length (Nominal cable outer diameter approx. 9.93 mm)
Operating Temp -20 deg C to +85 deg C
Power Consumption Passive interconnect assembly (Zero internal power draw)
Cable Type Multi-core system interconnection cable
Voltage Rating 300 V
Impedance Rating 120 ohm nominal characteristic impedance
Conductor Material High-quality copper with thermoplastic insulation
Shielding Integrated EMI shielding
System Compatibility Honeywell Safety Manager / FSC Systems

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The multi-core cable structure uses thermoplastic-insulated copper conductors surrounded by an overall EMI shield to maintain channel-to-channel isolation principles across parallel signal lines. Controlled 120 ohm nominal impedance minimizes transmission line reflections during high-speed digital communications, while physical dielectric isolation prevents high-frequency noise from coupling onto analog 4-20 mA HART loop protocol lines or discrete safety shutdown circuits.

Frequently Asked Questions

Q: What primary cabinet hardware interfaces are connected by the FS-SICC-0001/L8 cable assembly?

A: The cable interconnects Safety Manager system modules and chassis I/O slots to remote Field Termination Assemblies (FTAs).

Q: Can the cable assembly be disconnected while the connected I/O rack is energized?

A: Unplugging the cable severs active I/O communication between the controller chassis and the connected FTA; field signals or safety loops tied to the cable must be bypassed prior to physical removal.

Q: How does the overall EMI shield impact noise rejection in high-interference environments?

A: The continuous metallic shielding blocks external electromagnetic and radio-frequency interference from inducing noise voltages on low-level analog and digital field telemetry circuits.

Field Installation Guidelines

  • Route the 8 meter cable assembly through dedicated low-voltage cable trays or enclosure wireways, keeping clear of AC power lines and VFD output conductors.
  • Observe a minimum static bending radius along the cable run to avoid pinching internal copper conductors or tearing the outer EMI shield mesh.
  • Fully engage factory-terminated pin headers into mating chassis or FTA connectors and tighten retention hardware to ensure vibration-proof low-resistance contact.
  • Connect the cable shield drain wire directly to the cabinet protective earth (PE) ground bus bar at a single termination point to prevent circulating ground potential loops.