{"product_id":"mc-psrx04-51198947-100k-honeywell-power-system-housing","title":"MC-PSRX04 51198947-100K Honeywell Power System Housing","description":"\u003cp\u003eConfigured for centralized power distribution in Honeywell Distributed Control System platforms, the \u003cstrong\u003eHoneywell 51198947-100K\u003c\/strong\u003e (\u003cstrong\u003eMC-PSRX04\u003c\/strong\u003e Power System Housing) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-PSRX04 51198947-100K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Honeywell Rack Footprint (Thickness: 2.2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput: 115 VAC, Total Output: 0.565 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Ratings\u003c\/td\u003e\n\u003ctd\u003e20 A \/ 1 A \/ 0.035 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Processor Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 40 Processors (Redundant or Non-Redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eOne-on-one I\/O Redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Compatibility\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O, Digital I\/O, Smart Transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Protection\u003c\/td\u003e\n\u003ctd\u003eConformal Coating (CC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MC-PSRX04 Power System Housing distributes regulated power lines across backplane buses to drive digital, analog, and smart transmitter interface cards. Fully compatible with 4-20 mA HART loop protocol architectures, the backplane integrates robust channel-to-channel isolation and galvanic protection circuit paths. The conformally coated assembly protects copper traces against industrial atmospheric contaminants, preventing ground loops and common-mode noise propagation between redundant I\/O processor channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O processors can be installed within a single MC-PSRX04 housing assembly?\u003c\/p\u003e\n\u003cp\u003eA: The housing supports up to 40 redundant or non-redundant I\/O processors across its backplane slots.\u003c\/p\u003e\n\u003cp\u003eQ: What input and output power specifications govern the MC-PSRX04 backplane distribution?\u003c\/p\u003e\n\u003cp\u003eA: The housing accepts a nominal 115 VAC input and provides a total output power capacity of 0.565 kW with DC current rails rated at 20 A, 1 A, and 0.035 A.\u003c\/p\u003e\n\u003cp\u003eQ: How does conformal coating protect the backplane circuit board in harsh plant environments?\u003c\/p\u003e\n\u003cp\u003eA: Conformal coating applies a protective polymer layer over the printed circuit assembly, preventing moisture, chemical gases, and particulate matter from causing corrosion or parasitic electrical leakage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all 115 VAC primary power sources before mounting or servicing the MC-PSRX04 chassis.\u003c\/li\u003e\n\u003cli\u003eConfirm that the housing is bonded securely to the cabinet grounding bus using heavy-gauge earth grounding straps to suppress electrical noise.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate vertical airflow spacing above and below the chassis assembly to maintain thermal dissipation across full 0.565 kW load profiles.\u003c\/li\u003e\n\u003cli\u003eVerify that all processor card edge connectors are aligned correctly before fully seating modules into backplane slots.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52393190359336,"sku":"MC-PSRX04 51198947-100K","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/MC-PSRX0451198947-100K.jpg?v=1789552306","url":"https:\/\/www.powerdcs.com\/es\/products\/mc-psrx04-51198947-100k-honeywell-power-system-housing","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}