Specifications
Manufacturer: Honeywell
Product No.: MC-TAIH52
Condition: 10 Artículos en stock
Product Type: Analog Input Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Detalles de producto
Descripción
The Honeywell MC-TAIH52, also cataloged as the MC-TAIH52 Redundant High Level Analog Input Termination Assembly, operates as a dedicated hardware component for dual-redundant analog signal conditioning and distribution within Honeywell TDC 3000 and Experion PKS High Performance Process Manager (HPPM) platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | MC-TAIH52 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.35 kg |
| Dimensions | 12.00 x 30.50 x 3.80 cm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | Powered via 24 VDC I/O bus interface |
| Input Signal Type | High Level Analog Input (4-20 mA / 1-5 VDC) |
| Channel Configuration | 16 Channels (Redundant Architecture) |
| Redundancy Scheme | Dual-FTA / Dual-I/O Processor Redundancy |
| Isolation | System-to-Field Galvanic Isolation |
Channel Isolation & Fieldbus Signal Routing
The MC-TAIH52 provides dual-path signal routing for up to 16 high-level analog inputs, allowing concurrent interfacing with redundant High Level Analog Input (HLAI) processor cards. Designed to support 4-20 mA HART loop protocol transmitters and 1-5 VDC field signals, the assembly incorporates passive signal-splitting circuitry and channel-to-channel isolation. This ensures that a component failure or physical disconnection on a single I/O processor channel does not disrupt signal continuity or introduce loop impedance shifts on the primary control path.
Frequently Asked Questions
Q: How does the MC-TAIH52 handle redundancy between primary and backup analog input processors?
A: The board features dual cable connections that route incoming field loop currents across precision parallel sampling resistors, delivering identical voltage signals simultaneously to both primary and secondary HLAI modules.
Q: Can individual field wiring terminals be disconnected without removing the entire assembly?
A: Yes, field connections are terminated via screw compression terminal blocks, allowing field loop wiring to be isolated independently during troubleshooting without interrupting adjacent channels.
Q: Does the MC-TAIH52 require external power to execute signal routing?
A: No active onboard power conversion is required for basic passive scaling; 24 VDC transmitter loop power is distributed directly from the system power bus through fused branch circuits on the board.
Field Installation Guidelines
- Disconnect transmitter loop power and isolate backplane interface cables before installing or replacing the MC-TAIH52 assembly on the DIN rail or mounting plate.
- Ensure field input cables use individually shielded twisted pairs to maintain signal integrity across high-density analog loop runs.
- Connect signal cable shields directly to the cabinet ground bus at a single point to prevent ground potential loops from distorting measurement readings.
- Verify that both redundant interface cables are fully seated and locked with retention latches to guarantee continuous dual-processor communications.