Specifications

  • Manufacturer: Honeywell

  • Product No.: MC-THAO11 51309542-175

  • Condition: 10 Artículos en stock

  • Product Type: Analog Output Modules

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

Detalles de producto

Descripción

Configured for precise voltage and current signal generation in Honeywell Experion PKS and Series 8 systems, the Honeywell 51309542-175 (MC-THAO11 Analog Output Module) provides direct physical/electrical execution to field actuators and control loops. The hardware converts digital control commands into high-resolution analog outputs via an onboard 16-bit digital-to-analog converter matrix.

Hardware Specifications

Parameter Specification
Model MC-THAO11 (51309542-175)
Brand Honeywell
Origin USA / Global Manufacturing
Weight Approx. 0.45 kg
Dimensions Cabinet Standard Slot Dimensions
Operating Temp 0 to +50 deg C
Power Consumption Power Supplied via Backplane Interface
Module Type Analog Output Module
Signal Types 0-5 V, 1-5 V, 4-20 mA
Resolution 16-bit DAC
Accuracy +/-0.1% Full Scale
Isolation Channel-to-System Galvanic Isolation
System Compatibility Honeywell Series 8 / Experion PKS

DCS Process Control & 4-20 mA HART Loop Protocol

The MC-THAO11 Analog Output Module delivers continuous 4-20 mA HART loop protocol current signals and configurable voltage ranges (0-5 V, 1-5 V) for accurate drive of final control elements. Designed for low-latency update rates, the module maintains tight control loop stability in high-speed DCS applications.

Channel-to-system galvanic isolation protects internal processing logic against external field transients, earth loops, and common-mode voltage spikes. The 16-bit resolution DAC output stage reduces signal quantization error, maintaining consistent +/-0.1% full-scale accuracy across varying field loads.

Frequently Asked Questions

Q: What output signal types does the MC-THAO11 module support?

A: The module supports both standard voltage outputs (0-5 V, 1-5 V) and current loop outputs (4-20 mA) across multiple field channels.

Q: How does channel-to-system galvanic isolation protect the Honeywell Series 8 rack?

A: Galvanic isolation creates an electrical barrier between field wiring and the internal system backplane, preventing field ground loops and electrical surges from damaging central processing cards.

Q: Is special calibration required upon initial installation of the MC-THAO11 hardware?

A: Factory calibration maintains +/-0.1% full-scale accuracy under standard operating conditions; routine system loop checks verify DAC scaling against field device ranges during commissioning.

Field Installation Guidelines

  • Backplane Chassis Engagement: Align the module with the dedicated slot guides of the Honeywell Series 8 chassis and push firmly until edge connectors lock into the backplane bus.
  • Shield Grounding Protocols: Terminate output cable shields at the designated ground bar within the termination assembly, leaving the field actuator side ungrounded to avoid ground potential differentials.
  • Field Wiring Separation: Route 4-20 mA current loop wires and voltage output signal lines in separate cable trays away from high-voltage AC lines to prevent induced noise.