{"product_id":"mc-thao11-51309542-175-honeywell-analog-output-module","title":"MC-THAO11 51309542-175 Honeywell Analog Output Module","description":"\u003cp\u003eConfigured for precise voltage and current signal generation in Honeywell Experion PKS and Series 8 systems, the \u003cstrong\u003eHoneywell 51309542-175\u003c\/strong\u003e (\u003cstrong\u003eMC-THAO11\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution to field actuators and control loops. The hardware converts digital control commands into high-resolution analog outputs via an onboard 16-bit digital-to-analog converter matrix.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-THAO11 (51309542-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCabinet Standard Slot Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower Supplied via Backplane Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003e0-5 V, 1-5 V, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-System Galvanic Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Series 8 \/ Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe MC-THAO11 Analog Output Module delivers continuous 4-20 mA HART loop protocol current signals and configurable voltage ranges (0-5 V, 1-5 V) for accurate drive of final control elements. Designed for low-latency update rates, the module maintains tight control loop stability in high-speed DCS applications.\u003c\/p\u003e\n\u003cp\u003eChannel-to-system galvanic isolation protects internal processing logic against external field transients, earth loops, and common-mode voltage spikes. The 16-bit resolution DAC output stage reduces signal quantization error, maintaining consistent +\/-0.1% full-scale accuracy across varying field loads.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What output signal types does the MC-THAO11 module support?\u003c\/p\u003e\n\u003cp\u003eA: The module supports both standard voltage outputs (0-5 V, 1-5 V) and current loop outputs (4-20 mA) across multiple field channels.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-system galvanic isolation protect the Honeywell Series 8 rack?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic isolation creates an electrical barrier between field wiring and the internal system backplane, preventing field ground loops and electrical surges from damaging central processing cards.\u003c\/p\u003e\n\u003cp\u003eQ: Is special calibration required upon initial installation of the MC-THAO11 hardware?\u003c\/p\u003e\n\u003cp\u003eA: Factory calibration maintains +\/-0.1% full-scale accuracy under standard operating conditions; routine system loop checks verify DAC scaling against field device ranges during commissioning.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Chassis Engagement\u003c\/strong\u003e: Align the module with the dedicated slot guides of the Honeywell Series 8 chassis and push firmly until edge connectors lock into the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Protocols\u003c\/strong\u003e: Terminate output cable shields at the designated ground bar within the termination assembly, leaving the field actuator side ungrounded to avoid ground potential differentials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Separation\u003c\/strong\u003e: Route 4-20 mA current loop wires and voltage output signal lines in separate cable trays away from high-voltage AC lines to prevent induced noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52386086158632,"sku":"MC-THAO11 51309542-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/51309542-175MC-THAO11.png?v=1789463879","url":"https:\/\/www.powerdcs.com\/es\/products\/mc-thao11-51309542-175-honeywell-analog-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}