{"product_id":"mu-taih13-51309138-125-high-level-analog-input-fta-honeywell","title":"MU-TAIH13 51309138-125 High Level Analog Input FTA | Honeywell","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51309138-125\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU-TAIH13\u003c\/strong\u003e High Level Analog Input FTA, operates as a dedicated hardware component for field signal conditioning and analog input conversion within Honeywell TPS and Experion PKS platforms. It routes 16 independent analog channels receiving 4-20 mA and 0-10 V signals directly to central process controllers with high-resolution analog-to-digital conversion.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH13 (51309138-125)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox 8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 Analog Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003eBetter than 0.1 percent of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and system galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eType C Compression Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MU-TAIH13 (51309138-125) features channel-to-channel and system galvanic isolation to prevent ground loop currents from degrading signal accuracy across 4-20 mA current loops. Integrated signal conditioning and active filtering mitigate common-mode noise and cross-channel interference. This high-density isolation barrier allows reliable signal pass-through for 4-20 mA HART loop protocol telemetry, preserving measurement precision across high-vibration and electrically noisy cabinet wireways.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the MU-TAIH13 FTA be replaced under live system power?\u003c\/p\u003e\n\u003cp\u003eA: To prevent backplane bus communication errors and electrical transients, power down the rack segment or isolate the field termination assembly before insertion or removal.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module support high-availability redundant configurations?\u003c\/p\u003e\n\u003cp\u003eA: The hardware architecture allows parallel connection to dual I\/O cards, enabling seamless signal takeover in redundant controller setups without interrupting active loop processing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize system rack power prior to installing or removing the FTA module from the cabinet mounting structure.\u003c\/li\u003e\n\u003cli\u003eRoute incoming 4-20 mA and 0-10 V signals using shielded twisted-pair cabling to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eConnect signal cable shields to the main cabinet earth ground bus at a single point to preserve channel-to-channel isolation limits.\u003c\/li\u003e\n\u003cli\u003eTorque all Type C compression terminals to standard torque specs to ensure solid contact resistant to field vibration.\u003c\/li\u003e\n\u003cli\u003eMaintain unobstructed airflow around the FTA assembly so operating temperatures stay within the designated 0 to 60 deg C range.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52378760806696,"sku":"MU-TAIH13 51309138-125","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/MU-TAIH13.png?v=1789370835","url":"https:\/\/www.powerdcs.com\/es\/products\/mu-taih13-51309138-125-high-level-analog-input-fta-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}