P0917XV | FBM215/218 Foxboro Invensys Termination Assembly

Specifications

  • Manufacturer: Foxboro

  • Product No.: FBM215/218 P0917XV

  • Condition: 10 Artículos en stock

  • Product Type: Terminal Assemblies

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 800g

  • Shipping port: Xiamen

  • Warranty: 12 months

Detalles de producto

Descripción

The P0917XV is a Foxboro Invensys termination assembly configured for I/A Series control networks, supporting 8 isolated output channels for 4-20 mA DC loops with superimposed HART digital signals. It provides 600 V AC per-channel isolation, up to 750 Ohm load driving at 20 mA, and operation from -20 deg C to +60 deg C.

Signal Termination and Isolation

The P0917XV interfaces field actuators and controller backplane connections across 8 isolated output channels using a 3-tier compression terminal layout. Per-channel isolation rated at 600 V AC helps prevent ground loops and electrical noise coupling between individual field circuits.

Each loop supports 4-20 mA DC analog control alongside superimposed HART digital signaling up to a 750 Ohm maximum load at 20 mA. Keep loop resistance and field device burden within this 750 Ohm limit so analog current levels and HART digital communications remain within specification.

System Pairing and Environmental Ratings

Designed for I/A Series configurations associated with FBM215 and FBM218 modules, the P0917XV is loop-powered (passive) and operates from -20 deg C to +60 deg C. It meets ISA Standard S71.04 Class G3 requirements and measures 14.5 cm x 13.5 cm x 6.5 cm with a weight of 0.8 kg.

Verify module compatibility, DIN rail mounting space, and any required adapter hardware before installation. Where redundant FBM218 pairings or field device configuration tools are used, confirm exact system rules in your I/A Series project engineering documentation.

Technical Specifications

Parameter Specification
Model P0917XV
Brand Foxboro Invensys
Product Type Termination Assembly
System I/A Series
Channel Configuration 8 isolated output channels
Signal Compatibility 4-20 mA DC control loops with superimposed HART digital communication
Maximum Output Load 750 Ohm at 20 mA
Isolation 600 V AC per channel
Terminal Design 3-tier compression terminals
Power Supply Passive (loop powered)
Corrosive Environment Rating ISA Standard S71.04 Class G3
Operating Temperature -20 deg C to +60 deg C
Dimensions 14.5 cm x 13.5 cm x 6.5 cm
Weight 0.8 kg
Origin Manufacturer Standard

Field Installation Guidelines

  1. Mount the P0917XV onto a DIN rail inside the I/O cabinet with adequate clearance for wiring and heat dissipation.
  2. Connect field conductors to the 3-tier compression terminals and verify tight mechanical clamping on each wire.
  3. Terminate cable drain wires to the designated grounding bus bar while maintaining the 600 V AC per-channel isolation design.
  4. Confirm compatibility with the target FBM module (such as FBM215 or FBM218) before seating the module into the assembly connector.
  5. Perform loop and HART communication verification before putting the output channel into active service.

Frequently Asked Questions

Q: Can an FBM module be replaced on the Foxboro P0917XV without disconnecting field wiring?

A: The terminal assembly physical layout allows FBM module removal and replacement without disturbing field wiring, subject to system maintenance state and safety procedures. Confirm hot-swap and power-down rules for your specific FBM module and I/A Series revision before servicing.

Q: What are the wiring and load limits on the P0917XV output channels?

A: Each of the 8 isolated output channels supports up to 750 Ohm load at 20 mA for 4-20 mA and HART loop signaling. Verify loop impedance, cable capacitance, and distance limits against your specific I/O module specifications and field wiring layout.

Q: What is required when using redundant FBM218 modules with the P0917XV?

A: Source notes indicate that redundant FBM218 setups may require an adapter (such as RH916QD) to bridge dual-module signals to the 8-channel termination interface. Check your I/A Series hardware documentation to confirm exact adapter and redundancy requirements.

Cómo obtener una cotización

Rastreo de orden

Transportistas

Política y condiciones de reembolso

Condiciones de garantía

Productos relacionados