{"product_id":"tk-ixr061-analog-input-module-honeywell","title":"TK-IXR061 Analog Input Module | Honeywell","description":"\u003cp\u003eThe \u003cstrong\u003eTK-IXR061\u003c\/strong\u003e is a dedicated analog input module manufactured by Honeywell for multi-channel signal acquisition and processing within Experion control system platforms. Engineered for high-precision industrial measurement, this module provides six isolated analog input channels supporting 0-10 VDC voltage and 4-20 mA current instrumentation circuits.\u003c\/p\u003e\n\u003ch3\u003eSignal Isolation and Measurement Precision\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates 500 Vrms galvanic isolation between individual channels and system ground to suppress ground loop currents and transient voltage coupling. Utilizing a 16-bit analog-to-digital converter providing 65,536 steps with an accuracy of +-0.05% of full scale, it ensures stable signal digitization across wide ambient thermal profiles with a temperature coefficient of +-3 ppm\/deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module vertically on a standard 35 mm DIN rail inside protective industrial enclosures to maintain proper convection airflow. Maintain dedicated separation between 24 VDC field instrument wiring and high-voltage AC distribution conduits, and ensure all shield drain wires from field transmitter cables are bonded to a single cabinet ground point. Verify that input terminal blocks are locked securely and execute loop current testing prior to full controller commissioning.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-IXR061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signals\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC voltage, 4-20 mA current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u0026amp; Accuracy\u003c\/td\u003e\n\u003ctd\u003e16-bit (65,536 steps), +-0.05% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e+-3 ppm\/deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Impedance\u003c\/td\u003e\n\u003ctd\u003eVoltage \u0026gt; 2 kohm, Current \u0026lt; 600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 Vrms channel-to-channel and channel-to-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (18 to 30 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 3.5 W (4.3 W max power dissipation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e44.5 x 120 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.76 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Does the TK-IXR061 module support hot-swappable installation during system operation? A: Yes. The module features built-in circuit isolation that allows hot-swappable replacement under live cabinet power without disrupting adjacent I\/O modules on the chassis rail.\u003c\/p\u003e\n\u003cp\u003eQ: How does fault detection operate on active 4-20 mA input loops? A: The module continuously monitors loop impedance and current signal thresholds, flagging out-of-range conditions (\u0026lt; 3.8 mA or \u0026gt; 20.5 mA) and open-circuit wire breaks to the controller diagnostics layer.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68156294594856,"sku":"TK-IXR061","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/TK-IXR061_Cocoai.png?v=1794383844","url":"https:\/\/www.powerdcs.com\/es\/products\/tk-ixr061-analog-input-module-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}