{"product_id":"triconex-2770h-hart-interface-module","title":"Triconex 2770H HART Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003e2770H\u003c\/strong\u003e is a Triconex HART interface module that links HART-enabled field instruments with Triconex safety control systems. It supports 32 channels across 4-20 mA and 0-5 VDC signals, 1500 V AC channel-to-channel isolation, and a -40 deg C to +70 deg C operating range while keeping power consumption below 5 W.\u003c\/p\u003e\n\u003ch3\u003eHART Communication and Signal Handling\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e2770H\u003c\/strong\u003e supports HART revisions 5.0, 6.0, and 7.0 to exchange secondary variables and device diagnostic data with smart field devices. Digital HART data is acquired without interrupting primary analog signal paths, updating at up to 4 updates\/sec per channel.\u003c\/p\u003e\n\u003cp\u003eEach module provides 32 channels configured for 4-20 mA or 0-5 VDC signals, with 1500 V AC channel-to-channel isolation protecting internal circuitry and backplane paths. Power draw stays below 5 W, limiting heat dissipation inside densely populated control cabinets.\u003c\/p\u003e\n\u003ch3\u003eModule Pairing and Multiplexing\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e2770H\u003c\/strong\u003e pairs with Triconex 3700A and 3721 analog input modules for Triple Modular Redundant (TMR) safety architectures. System engineers deploy it in Safety Instrumented Systems (SIS) and process safety applications where smart transmitter diagnostics are required alongside analog input monitoring.\u003c\/p\u003e\n\u003cp\u003eWhere multiplexing is used in the system layout, the \u003cstrong\u003e2770H\u003c\/strong\u003e works with the 2071H HART multiplexer configuration incorporating the 4850 multiplexer. Exact chassis slot assignment, termination assemblies, and multiplexer wiring depend on the Tricon system configuration and paired analog input modules.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2770H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHART Interface Module (HART Analog Input Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA or 0-5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Protocol Support\u003c\/td\u003e\n\u003ctd\u003eRevisions 5.0, 6.0, 7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Rate\u003c\/td\u003e\n\u003ctd\u003e4 updates\/sec per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 V AC (channel-to-channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eless than 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003e3700A and 3721 analog input modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiplexing Support\u003c\/td\u003e\n\u003ctd\u003e4850 Multiplexer when used with 2071H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Which analog input modules pair with the Triconex 2770H?\u003c\/p\u003e\n\u003cp\u003eA: The \u003cstrong\u003e2770H\u003c\/strong\u003e is specified for use with Triconex 3700A and 3721 analog input modules. Confirm that your existing I\/O architecture uses one of these supported analog input modules before ordering.\u003c\/p\u003e\n\u003cp\u003eQ: What HART versions and signal types does the 2770H support?\u003c\/p\u003e\n\u003cp\u003eA: It supports HART revisions 5.0, 6.0, and 7.0 across 32 channels handling 4-20 mA or 0-5 VDC signals. Check field transmitter specifications to verify compatibility with the target HART revision and electrical signal range.\u003c\/p\u003e\n\u003cp\u003eQ: How is multiplexing handled with the 2770H?\u003c\/p\u003e\n\u003cp\u003eA: The \u003cstrong\u003e2770H\u003c\/strong\u003e supports integrated multiplexing using the 4850 multiplexer when paired with the 2071H. Verify your system multiplexer hardware and termination layout against your Tricon project drawings.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":68233559572776,"sku":"2770H","price":327.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/2755-020_Cocoai_9e3186ba-3733-446e-aa2b-96fe5dc9b0e2.png?v=1795052588","url":"https:\/\/www.powerdcs.com\/es\/products\/triconex-2770h-hart-interface-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}