Triconex EM 2291 Internal System Interface Module

Specifications

  • Manufacturer: Triconex

  • Product No.: EM 2291

  • Condition: 10 Artículos en stock

  • Product Type: System Interface Modules

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Detalles de producto

Descripción

The Triconex EM 2291 is an internal system interface module designed for Triconex Safety Instrumented Systems (SIS). Installed in a system chassis, it operates from a 24 VDC nominal power supply and supports fault-tolerant safety architectures across a -20 deg C to +60 deg C operating range.

System Role and Configuration

Within a Triconex safety control architecture, the Triconex EM 2291 provides an internal system interface function and is designated in the provided documentation as an I/O module. Chassis-based mounting keeps the module mechanically seated within the rack assembly for cabinet and panel integration.

The module operates from a nominal 24 VDC supply and is rated for non-condensing humidity from 5% to 95%. Where redundant or fault-tolerant configurations are deployed at the system level, hardware and chassis layout must follow the specific Triconex system design.

Technical Specifications

Parameter Specification
Model EM 2291
Brand Triconex
Product Type Internal System Interface Module / I/O Module
Power Supply 24 VDC nominal
Dimensions 10.2" x 6.3" x 3.1"
Weight 2.2 lbs
Mounting Chassis-based installation
Operating Temperature -20 deg C to +60 deg C
Storage Temperature -40 deg C to +85 deg C
Humidity Range 5% to 95%, non-condensing

Installation and Environmental Limits

Mount the module securely inside a compatible Triconex chassis in an environment maintained between -20 deg C and +60 deg C during operation. When stored prior to installation, keep conditions within -40 deg C to +85 deg C and avoid moisture condensation across the 5% to 95% humidity range.

Frequently Asked Questions

Q: What power supply does the Triconex EM 2291 require?

A: It operates from a 24 VDC nominal power supply. Verify that the system power distribution matches the 24 VDC nominal rating before energizing the chassis.

Q: How is the Triconex EM 2291 mounted?

A: It uses chassis-based installation rather than standalone surface mounting. Confirm that the target chassis provides an open slot and matches the 10.2" x 6.3" x 3.1" envelope.

Q: What temperature and humidity limits apply to this module?

A: The rated operating temperature is -20 deg C to +60 deg C, and the storage temperature range is -40 deg C to +85 deg C. Relative humidity must stay between 5% and 95%, non-condensing.