10101/2/3 | Honeywell | Fail-Safe Digital Input Module
Specifications
Manufacturer: Honeywell
Product No.: 10101/2/3
Condition: 10 Items in Stock
Product Type: Digital Input Modules
Payment:T/T, Western Union
Weight: 1500g
Shipping port: Xiamen
Warranty: 12 months
Product details
Description
Configured for 16-channel digital signal acquisition in Honeywell DCS platforms, the Honeywell 10101/2/3 (10101 Digital Input Module) provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 10101/2/3 |
| Brand | Honeywell |
| Origin | Netherlands |
| Channels | 16 digital input channels |
| Input Type | Digital |
| Input Voltage | 24 VDC to 48 VDC |
| Input Current | 2 mA |
| Output Type | Dry contact |
| Output Voltage | 24 VDC |
| Output Current | 5 A |
| Power Supply | 48 VDC |
| Power Consumption | 10 W |
| Operating Temp | -40 to 70 deg C |
| Storage Temp | -40 to 85 deg C |
| Humidity | 0% to 95% non-condensing |
| Mounting | DIN rail |
| Weight | 1.5 kg |
| Dimensions | 230 mm x 130 mm x 60 mm (W x H x D) |
Channel Isolation & Field Signal Loop Execution
Designed for high-reliability process monitoring, the module incorporates channel-to-channel isolation and galvanic barriers to maintain signal integrity under common-mode noise conditions. It processes field inputs from switches, sensors, and alarm circuits operating across 24 VDC to 48 VDC thresholds. Onboard galvanic isolation isolates the field wiring from backplane control logic, preventing transient voltage spikes and ground loops from degrading signal processing performance across DCS node networks.
Frequently Asked Questions
Q: How is physical electrical isolation maintained across the input channels?
A: Internal optical and galvanic isolation barriers separate the field-side input circuits from the system backplane logic, preventing transient voltage spikes from propagating into the main controller.
Q: What mounting hardware is required for cabinet installation?
A: The module mounts directly onto a standard 35 mm DIN rail inside the enclosure, secured via integrated retention clips.
Q: How does the module handle power dissipation under max load?
A: The module dissipates up to 10 W under full 16-channel load, relying on natural convection airflow within a temperature enclosure maintained between -40 and 70 deg C.
Field Installation Guidelines
- Mount the module onto a standard DIN rail inside an IP54 or equivalent protective enclosure before connecting field wiring.
- Verify that the field power supply is de-energized and regulated within the 24 VDC to 48 VDC range prior to termination.
- Terminate shielded cables to dedicated grounding rails, ensuring single-point earthing to mitigate electromagnetic interference.
- Maintain proper conductor bend radii inside wire troughs to eliminate mechanical stress on screw terminals.
- Ensure unobstructed vertical cabinet airflow around the heat sink fins to maintain ambient temperatures within the -40 to 70 deg C operating window.