8C-PAIH51 51454362-175 Honeywell Series 8 HART Analog Input Module

Specifications

  • Manufacturer: Honeywell

  • Product No.: 8C-PAIH51 51454352-175

  • Condition: 10 Items in Stock

  • Product Type: Analog Input Modules

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 100g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product details

Description

Configured for analog signal acquisition and HART protocol communication in Honeywell Series 8 DCS platforms, the Honeywell 8C-PAIH51 51454362-175 (8C-PAIH51 HART Analog Input Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 8C-PAIH51 51454362-175
Brand Honeywell
Origin USA
Weight 0.3 kg
Dimensions 61 mm x 157 mm x 144 mm
Operating Temp Standard Series 8 rating (Unspecified exact range)
Power Consumption Unspecified (24 VDC nominal operating loop supply)
Part Number 51454362-175
Signal Channels Analog input with HART digital communication overlay
Wire Gauge Support Up to 12 AWG (2.5 mm2) stranded wire
Termination Connection Removable modular field connector on Series 8 IOTA

Process Control & HART Loop Characteristics

The 8C-PAIH51 51454362-175 module processes field analog measurements while maintaining full 4-20 mA HART loop protocol pass-through to Experion PKS system networks. Built-in channel-to-channel isolation limits ground loop disruption and cross-channel electrical interference across high-density field wiring runs. Integrated digital processing circuitry enables real-time extraction of secondary HART variables, device diagnostics, and dynamic calibration parameters directly into DCS database blocks without dampening primary analog loop update rates.

Frequently Asked Questions

Q: How are field wiring connections made to the 8C-PAIH51 51454362-175 hardware assembly?

A: Field connections attach via removable Series 8 modular terminal connectors mounted on the matching IOTA block, accepting wire gauges up to 12 AWG (2.5 mm2) stranded conductor.

Q: Is field wiring removal supported without disconnecting individual conductors during maintenance?

A: Yes, the modular connector design permits complete removal and insertion of the wired terminal block from the assembly to facilitate rapid module swapping and loop checkouts.

Q: Does the 8C-PAIH51 51454362-175 module require external signal isolators for HART loop communication?

A: No, the module incorporates internal channel isolation and direct HART modem extraction across field loop signals.

Field Installation Guidelines

  • IOTA Mounting: Seat the 8C-PAIH51 51454362-175 module into the designated slot on the Series 8 Input Output Termination Assembly (IOTA) and secure the retaining mechanisms to establish backplane connection.
  • Modular Wiring: Strip field conductors to length and secure inside the removable connector terminals up to 12 AWG (2.5 mm2). Ensure terminal screws are torqued properly to maintain reliable low-resistance electrical contact.
  • Shield Continuity: Terminate overall analog cable shields at the dedicated cabinet earth busbar using low-impedance grounding clamps to prevent ambient high-frequency noise from corrupting HART digital data streams.

How to Get a Quote