8C-PAIN01 51454356-175 | Honeywell | Series 8 Analog Input Module
Specifications
Manufacturer: Honeywell
Product No.: 8C-PAIN01 51454356-175
Condition: 10 Items in Stock
Product Type: Analog Input Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Product details
Description
The Honeywell 8C-PAIN01 51454356-175 serves as the primary 8C-PAIN01 Analog Input Module utilized to execute field instrument analog data acquisition across Experion PKS Series 8 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 8C-PAIN01 51454356-175 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.32 - 0.45 kg |
| Dimensions | 157 mm x 106 mm x 35 mm |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | Unspecified (24 VDC system rail) |
| Part Number | 51454356-175 |
| Input Channels | 16 single-ended analog input channels |
| Signal Types Supported | 4-20 mA, +-40 mA range, 0-10 V |
| Input Impedance | > 10 Mohm |
| Accuracy & Resolution | +-0.1% of full scale; 16-bit ADC |
| Isolation | 1000 VAC RMS or +-1000 VDC |
| Overload Protection | 120% for 2 seconds; 150% for 0.1 seconds |
| Common Mode Rejection | > 60 dB at 120 Hz |
Process Instrumentation Signal Conditioning & CJC
The 8C-PAIN01 51454356-175 module conditions low-level analog currents and voltages via its 16 single-ended channels using a 16-bit analog-to-digital converter (ADC). Designed for continuous process monitoring, the assembly incorporates galvanic isolation rated at 1000 VAC RMS (or +-1000 VDC) and dynamic common mode rejection (> 60 dB at 120 Hz) to eliminate field loop interference. Channel-to-channel signal processing natively accommodates 4-20 mA HART loop protocol pass-through communication alongside direct voltage measurements.
Frequently Asked Questions
Q: What is the isolation threshold between the signal terminals and system electronics on the 8C-PAIN01 51454356-175?
A: The module provides hardware isolation rated at 1000 VAC RMS or +-1000 VDC to prevent common-mode voltage spikes from damaging backplane electronics.
Q: How does the 8C-PAIN01 51454356-175 handle temporary current overloads on field input channels?
A: The inputs feature built-in overload protection capable of withstanding 120% full scale for up to 2 seconds and 150% full scale for up to 0.1 seconds.
Q: What input impedance does the module present to field transmitters?
A: The input circuitry maintains an input impedance exceeding 10 Mohm to minimize loading errors on connected instrument loops.
Field Installation Guidelines
- IOTA Chassis Installation: Align the 8C-PAIN01 51454356-175 card with the dedicated slot on the Series 8 Input Output Termination Assembly (IOTA) carrier and seat the backplane pins before securing retention hardware.
- Shield Cable Earthing: Terminate single-ended analog signal cable drain wires directly to the main cabinet grounding bus to maintain shield continuity and noise rejection.
- Wiring Routing Restrictions: Keep analog input signal conductors isolated from AC power distribution lines and high-current relay cabling within panel wiring ducts.