{"product_id":"8c-sdox01-honeywell-series-8-digital-output-module","title":"8C-SDOX01 Honeywell Series 8 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-SDOX01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8C-SDOX01\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete signal execution within Honeywell Experion PKS C300 Controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-SDOX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSeries 8 vertical I\/O form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eUnspecified (-40 to +70 deg C standard industrial class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eUnspecified (24 VDC system power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC Discrete \/ Digital Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eSupported via redundant IOTA carrier configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell C300 Controller \/ Experion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation \u0026amp; Bus Loop Protocols\u003c\/h3\u003e\n\u003cp\u003eThe 8C-SDOX01 processes discrete control outputs transmitted from the C300 controller via the Series 8 backplane, converting logic commands into 24 VDC physical signals to drive final control elements such as solenoids, indicators, and interlock relays. The module incorporates robust channel-to-channel isolation and surge protection to prevent transient electrical noise, field ground loops, and reverse inductive spikes from impairing system backplane communication or adjacent I\/O point operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 8C-SDOX01 module support removal and insertion under power (RIUP) during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, RIUP (hot-swapping) is supported when mounted on compatible Series 8 IOTA bases, permitting module maintenance without interrupting active bus communication on neighboring slots.\u003c\/p\u003e\n\u003cp\u003eQ: How does the 8C-SDOX01 handle short circuits or electrical faults on field output channels?\u003c\/p\u003e\n\u003cp\u003eA: Internal current-limiting circuitry and protective isolation prevent localized short-circuit conditions on individual field wiring loops from propagating back to the main control electronics.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 8C-SDOX01 be deployed in redundant I\/O configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, redundant output topologies are achieved by pairing modules on redundant IOTA base units configured within the Experion PKS control builder environment.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Carrier Mounting\u003c\/strong\u003e: Align the card edge contacts with the targeted slot on the Series 8 IOTA carrier and press firmly until the mechanical locking tabs engage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield \u0026amp; Grounding\u003c\/strong\u003e: Terminate overall cable shields and drain wires at a single grounding bar within the control cabinet to eliminate stray electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation\u003c\/strong\u003e: Ensure 24 VDC discrete output wiring is routed through raceways separate from high-voltage AC power lines and drive output cables.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52312976687400,"sku":"8C-SDOX01","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/8C-PAIMA151454473-1751_dd619af4-1526-4b25-9613-cbbefd2ba42a.png?v=1788255837","url":"https:\/\/www.powerdcs.com\/products\/8c-sdox01-honeywell-series-8-digital-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}