{"product_id":"8u-taida1-honeywell-series-c-analog-input-module","title":"8U-TAIDA1 Honeywell Series C Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 8U-TAIDA1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8U-TAIDA1\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for analog field signal acquisition within Honeywell Experion PKS C300 controller systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8U-TAIDA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 26.7 cm x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane powered via Experion C300 IOTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 differential analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e-10 V to +10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Input Range\u003c\/td\u003e\n\u003ctd\u003e0-100 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Loop Power Management and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8U-TAIDA1 conditions high-accuracy analog signals originating from field transmitters across eight differential channels. The hardware supports 4-20 mA HART loop protocol current transmitters, voltage sources up to +\/-10 V, and resistive sensors up to 100 ohm. Channel-to-channel isolation and galvanic suppression prevent field ground loops from degrading signal integrity before internal 12-bit analog-to-digital conversion occurs. Integrated surge filters clip electrical transients on incoming field lines to protect the internal digital bus interface during steady-state processing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can 4-20 mA loop transmitters be connected directly to the differential input channels of the 8U-TAIDA1?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module accepts standard 4-20 mA current signals across its differential inputs alongside voltage and resistance ranges.\u003c\/p\u003e\n\u003cp\u003eQ: What analog conversion resolution is provided across the input ranges?\u003c\/p\u003e\n\u003cp\u003eA: The onboard analog-to-digital converters process all configured input signals at 12-bit resolution with an overall accuracy of +\/-0.1% of full scale.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 8U-TAIDA1 support online module insertion and removal?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is supported when installed on compatible Experion PKS Series C I\/O Termination Assemblies (IOTA) without removing backplane power.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down field instrument loop supplies prior to connecting or wiring signal leads to the IOTA terminal blocks.\u003c\/li\u003e\n\u003cli\u003eAlign the 8U-TAIDA1 card edges with the plastic guide rails of the target Series C assembly slot.\u003c\/li\u003e\n\u003cli\u003eSeat the module firmly into the backplane pin connector and tighten the top and bottom captive retaining screws to secure mechanical grounding.\u003c\/li\u003e\n\u003cli\u003eConnect individual channel wiring using twisted shielded pair conductors for all 4-20 mA current and voltage signals.\u003c\/li\u003e\n\u003cli\u003eTerminate wire shields at the dedicated chassis ground bar at one end only to prevent differential ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify channel selection parameters and input ranges in the Experion builder software prior to placing loops into active control modes.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52321536442664,"sku":"8U-TAIDA1","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/8C-PAIMA151454473-1751_2e4d16a6-00c9-4e3d-ba58-90a6ff294499.png?v=1788418081","url":"https:\/\/www.powerdcs.com\/products\/8u-taida1-honeywell-series-c-analog-input-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}