900G02-0001 Honeywell ControlEdge HC900 Digital Input Module
Specifications
Manufacturer: Honeywell
Product No.: 900G02-0001
Condition: 10 Items in Stock
Product Type: Digital Input Modules
Payment:T/T, Western Union
Weight: 250g
Shipping port: Xiamen
Warranty: 12 months
Product details
Description
Configured for 16-point digital input signal processing in ControlEdge HC900 architectures, the Honeywell 900G02-0001 (900G02-0001 Digital Input Module) provides direct physical/electrical execution of 24 VDC field contact state sensing.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 900G02-0001 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.25 kg |
| Dimensions | Standard ControlEdge HC900 I/O card footprint |
| Operating Temp | 0 to +60 deg C |
| Power Consumption | 3 to 5 W (typical) |
| Product Type | Digital Input Modules |
| Input Channels | 16 |
| Input Voltage | 24 VDC |
| Isolation Type | Optical isolation per channel group |
| Mounting Type | Controller rack or chassis system |
Channel-to-Channel Isolation and 4-20 mA HART Loop Protocol
The module incorporates integrated optical isolation barriers per channel group to decouple field contact wiring from the internal system backplane logic. Input signal conditioning circuits feature hardware-based digital filtering to eliminate mechanical contact bounce and attenuate line noise transients. While dedicated to discrete 24 VDC sensing, the module operates in parallel with analog I/O channels, maintaining total signal independence from adjacent 4-20 mA HART instrumentation loops traversing the same cabinet backplane.
Frequently Asked Questions
Q: What input signal voltage level does the 900G02-0001 module accept?
A: The module is engineered specifically for standard nominal 24 VDC discrete field signals.
Q: How does the module handle high-frequency electrical noise and contact bounce?
A: Each input channel utilizes optical isolation coupled with internal RC filtering circuits to suppress contact bounce and external electromagnetic interference.
Field Installation Guidelines
- Ensure the controller rack assembly power is fully de-energized prior to inserting or removing the digital input module.
- Align the module circuit board with the designated rack slot guide rails and push firmly until backplane bus connectors seat.
- Use shielded cabling for field switch contact wiring in high-EMI environments, terminating shield drain wires to cabinet earth ground.
- Verify field supply voltage polarity and amplitude remain within 24 VDC operating thresholds before energizing input loops.