{"product_id":"abb-sf810int-foc-uv-t-l-flame-scanner-uvisor™-sf810-series","title":"ABB SF810INT-FOC-UV-T-L Flame Scanner – Uvisor™ SF810 Series","description":"\u003ch3\u003eABB SF810INT-FOC-UV-T-L – UV Flame Scanner (Uvisor™ SF810 Series)\u003c\/h3\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB SF810INT-FOC-UV-T-L\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust UV flame scanner from the Uvisor™ SF810 series, engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial burner monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein harsh combustion environments. Equipped with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efiber optic cable (FOC) system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSiC UV photodiode sensor\u003c\/strong\u003e, it ensures reliable detection of flame presence even in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecorner-fired tilting burners and deep windbox installations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere direct optical sight is impractical.\u003c\/p\u003e\n\u003cp\u003eThis flame scanner integrates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant communication ports, relay outputs, and analog signals\u003c\/strong\u003e, making it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation, petrochemical plants, and industrial boilers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring precise combustion safety and monitoring.\u003c\/p\u003e\n\u003ch3\u003e⚙️ Technical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSF810INT-FOC-UV-T-L\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eABB Uvisor™ SF810 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eUV solid-state SiC photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Response\u003c\/td\u003e\n\u003ctd\u003ePeak at 280 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eFiber optic cable with guide pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (18–29 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.6 W typical; 4 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e6 A peak, 2 ms settling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame Relay Output\u003c\/td\u003e\n\u003ctd\u003e1 NO contact, 240 VAC \/ 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, galvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e2 opto-coupled, 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDual RS-485 (Modbus RTU, Profibus DP-V1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Interface\u003c\/td\u003e\n\u003ctd\u003e4 push-buttons + 3-digit LED display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLens Cleaning Air Flow\u003c\/td\u003e\n\u003ctd\u003e400 l\/min (14 SCFM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Air Pressure\u003c\/td\u003e\n\u003ctd\u003e300 mm H₂O above windbox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Temp (FOC Tip)\u003c\/td\u003e\n\u003ctd\u003e350°C (662°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e135 mm × 67.5 mm × 28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5–1.3 kg (varies by config)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland (CH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50614947348776,"sku":"SF810INT-FOC-UV-T-L","price":368.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/ABBSF810INT-FOC-UV-T-L.jpg?v=1756957861","url":"https:\/\/www.powerdcs.com\/products\/abb-sf810int-foc-uv-t-l-flame-scanner-uvisor%e2%84%a2-sf810-series","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}