{"product_id":"cc-paih01-experion-pks-c300-analog-input-module-honeywell","title":"CC-PAIH01 Experion PKS C300 Analog Input Module | Honeywell","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIH01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-PAIH01\u003c\/strong\u003e Analog Input with HART Module, operates as a dedicated hardware component for high-level current signal acquisition and digital field telemetry routing within Experion PKS C300 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAIH01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg (shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C300 I\/O Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Type\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Input with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channel Topology\u003c\/td\u003e\n\u003ctd\u003eSupports differential inputs on channels 13 through 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePMIO Equivalent Type\u003c\/td\u003e\n\u003ctd\u003eHLAIHART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003e4-20 mA HART loop protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation Execution\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAIH01 processes 16 high-level analog current loops, maintaining continuous digital bidirectional data flow via the 4-20 mA HART loop protocol. Channels 13 through 16 incorporate dedicated differential input circuitry to suppress ground potential differences across complex instrumentation networks. The onboard signal conditioning channels enforce strict system-side galvanic isolation, preventing severe electrical noise and common-mode voltage surges from propagating into the core C300 controller backplane.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are differential input configurations assigned on the CC-PAIH01 module?\u003c\/p\u003e\n\u003cp\u003eA: Differential input capability is wired and assigned strictly to channels 13 through 16, whereas channels 1 through 12 operate under standard single-ended analog input signal topologies.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CC-PAIH01 module pass HART digital pass-through data to asset management software?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the onboard HART modem circuitry extracts digital primary, secondary, tertiary, and quaternary variables from the 4-20 mA analog loop signal and forwards them over the backplane to Experion PKS asset management tools.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module hot-swappable on an active C300 IOTA baseplate?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the hardware supports online insertion and removal (hot-swapping) on an energized IOTA without disrupting backplane communications or requiring a controller restart.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign the module rear connectors with the target slot on the C300 IOTA carrier and push firmly until the locking tabs snap into place.\u003c\/li\u003e\n\u003cli\u003eRoute 4-20 mA loop cables through dedicated wire troughs, ensuring a minimum 200 mm clearance from high-voltage AC conductors to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect signal cable shield drain wires to the cabinet grounding bar at a single termination point to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring polarity for 2-wire transmitter loops before energizing channel power rails.\u003c\/li\u003e\n\u003cli\u003eProvide a minimum vertical clearance zone of 100 mm above and below the assembly to allow natural thermal convection airflow across the housing.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52357513117992,"sku":"CC- PAIH01","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-PAIX0151405038-275_Cocoai_aa244ce7-5233-4046-a367-7148126aeed2.png?v=1788942425","url":"https:\/\/www.powerdcs.com\/products\/cc-paih01-experion-pks-c300-analog-input-module-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}