{"product_id":"cc-paih02-51405038-375-experion-pks-high-level-analog-input-module-honeywell","title":"CC-PAIH02 51405038-375 Experion PKS High-Level Analog Input Module | Honeywell","description":"\u003cp\u003eConfigured for high-level signal acquisition in Experion PKS Series-C control systems, the \u003cstrong\u003eHoneywell CC-PAIH02 51405038-375\u003c\/strong\u003e (\u003cstrong\u003eCC-PAIH02\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. It handles 16 analog input channels across Input\/Output Termination Assembly (IOTA) bus structures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAIH02 51405038-375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 channels (12 single-ended, 4 differential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e0-5 V, 1-5 V, 0.4-2 V, 4-20 mA (via internal 250 ohm resistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.075% of full scale (at 23.5 deg C +\/- 2 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 Mohm (for voltage inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection Ratio\u003c\/td\u003e\n\u003ctd\u003e70 dB (DC to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection Ratio\u003c\/td\u003e\n\u003ctd\u003e19 dB (at 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAIH02 51405038-375 analog input module digitized process variables using a high-precision 16-bit A\/D converter across a fast 50 ms scan cycle. Each channel interfaces directly with 2-wire or self-powered field transmitters utilizing the 4-20 mA HART loop protocol, as well as 0-5 V, 1-5 V, and 0.4-2 V voltage signals. The internal circuit architecture maintains robust signal conditioning and noise suppression, delivering 70 dB CMRR to safeguard backplane communications against field-side electrical interference and ground loop offsets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the CC-PAIH02 module convert 4-20 mA current signals into internal voltage measurements?\u003c\/p\u003e\n\u003cp\u003eA: Current loops are converted into voltage signals internally across precision 250 ohm dropping resistors integrated within the module circuit path.\u003c\/p\u003e\n\u003cp\u003eQ: Can single-ended and differential field inputs be mixed on the same CC-PAIH02 module?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module natively accommodates up to 12 single-ended channels and 4 differential channels according to the terminal assignments on the corresponding IOTA assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the Series-C IOTA base securely to the cabinet frame or DIN rail prior to inserting the CC-PAIH02 module.\u003c\/li\u003e\n\u003cli\u003eAlign the module edge connector pins carefully with the IOTA connector slot and push firmly until the locking tabs snap into place.\u003c\/li\u003e\n\u003cli\u003eTerminate 4-20 mA signal wires onto the designated IOTA screw terminals, verifying correct polarity for 2-wire loop-powered or self-powered field transmitters.\u003c\/li\u003e\n\u003cli\u003eSeparate low-voltage analog signal cables from high-voltage AC power wiring by at least 200 mm to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shield drains to the cabinet single-point grounding bar to establish effective ground loop isolation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52357242192168,"sku":"CC-PAIH02 51405038-375","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-PAIH0251405038-3751.png?v=1788938965","url":"https:\/\/www.powerdcs.com\/products\/cc-paih02-51405038-375-experion-pks-high-level-analog-input-module-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}