{"product_id":"cc-taix11-51308365-175-analog-input-module-honeywell","title":"CC-TAIX11 51308365-175 Analog Input Module | Honeywell","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAIX11 51308365-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TAIX11\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-channel analog signal acquisition and process variable digitization within Honeywell TotalPlant Solution (TPS) platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAIX11 51308365-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e29.4 x 12 x 7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRedundant Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51308365-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, thermocouples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0-5 V or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e+\/-0.02%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe CC-TAIX11 module captures voltage, current, and thermocouple process signals across redundant channel pathways. Operating on standard 4-20 mA current loop interfaces and voltage spans, the internal circuitry integrates channel-to-channel isolation barriers that eliminate ground loop potential differences between field transmitters and central control buses. Galvanic isolation buffers filter electrical noise interference, maintaining signal fidelity across high-accuracy analog digital conversion stages.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-TAIX11 support hot-swapping during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CC-TAIX11 supports online hot-swapping, enabling replacement of a faulty module without removing backplane power or disturbing continuous system control execution.\u003c\/p\u003e\n\u003cp\u003eQ: How does the redundant configuration function on the CC-TAIX11?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates redundant input channels that run parallel processing loops, allowing immediate failover execution if a signal path or hardware failure is detected.\u003c\/p\u003e\n\u003cp\u003eQ: What power input voltage is required for the CC-TAIX11?\u003c\/p\u003e\n\u003cp\u003eA: The module operates from a standard 24 VDC system power rail provided through the backplane assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign the CC-TAIX11 module with the designated backplane card guides and insert firmly until the edge connector fully seats.\u003c\/li\u003e\n\u003cli\u003eRoute 4-20 mA current loop and thermocouple field cables through designated wire ducts, maintaining physical separation from high-voltage AC lines.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring cable shields to the cabinet grounding bar at a single point to prevent ground loop currents from introducing measurement offset errors.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC power supply voltage remains within operational limits prior to energizing the analog channels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52342877192488,"sku":"CC-TAIX11 51308365-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-TAIX1151308365-175_Cocoai.png?v=1788768204","url":"https:\/\/www.powerdcs.com\/products\/cc-taix11-51308365-175-analog-input-module-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}