{"product_id":"cc-taon11-51306521-175-honeywell-analog-output-module","title":"CC-TAON11 51306521-175 Honeywell Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAON11 51306521-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TAON11\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for converting digital controller commands into 16 channels of 4 to 20 mA DC current signals within Experion PKS Series C platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAON11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via Series C I\/O Link and 24 VDC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 Output Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Resistance\u003c\/td\u003e\n\u003ctd\u003e750 ohms at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003eSystem logic to field wiring isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eThe CC-TAON11 module integrates 4-20 mA HART loop protocol capabilities across its 16 output channels, enabling bi-directional digital data transfer superimposed onto standard analog control signals. This architecture allows the module to pass HART pass-through field device diagnostics, calibration parameters, and multivariable telemetry directly between smart positioners or final control elements and the Experion PKS system layer. Channel-to-system galvanic isolation protects internal processing logic against field loop transients, ensuring low total harmonic distortion and maintaining stable signal integrity across loop loads up to 750 ohms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-TAON11 support online hot-swap replacement without shutting down the controller?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module features a hot-swappable design that allows physical removal and replacement under power without interrupting system I\/O link communications or bringing down adjacent control loops.\u003c\/p\u003e\n\u003cp\u003eQ: What onboard diagnostic capabilities are available for field loop wiring fault detection?\u003c\/p\u003e\n\u003cp\u003eA: The module executes continuous self-checking logic to detect open-wire circuits, short circuits, and out-of-range current loops, instantly reporting fault states to the system controller.\u003c\/p\u003e\n\u003cp\u003eQ: How is high availability achieved for mission-critical output loops using this module?\u003c\/p\u003e\n\u003cp\u003eA: The CC-TAON11 can be deployed in a redundant hardware pair configuration within the Series C terminal assembly to maintain uninterrupted current generation in the event of a single module fault.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical Cabinet Mounting:\u003c\/strong\u003e Mount the assembly in the standard Series C vertical orientation on the terminal block to maintain unimpeded convection airflow across the module casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC Bus Powering:\u003c\/strong\u003e Verify that field loop power connections supply a clean 24 VDC source capable of driving up to 750 ohms load impedance across all active current loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect field cable shielding to the designated cabinet earth ground bus at a single point to prevent circulating ground currents from corrupting analog output precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Terminations:\u003c\/strong\u003e Secure all field conductors into the I\/O terminal assembly using proper ferrule crimps, verifying mechanical tightness before energizing the I\/O bus.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52342887121192,"sku":"CC-TAON11 51306521-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-TAON1151306521-175_Cocoai.png?v=1788769236","url":"https:\/\/www.powerdcs.com\/products\/cc-taon11-51306521-175-honeywell-analog-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}