CC-TAOX51 Honeywell Experion PKS Series-C HART Analog Output Module
Specifications
Manufacturer: Honeywell
Product No.: CC-TAOX51
Condition: 10 Items in Stock
Product Type: Analog Output Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Product details
Description
The Honeywell CC-TAOX51, also cataloged as the CC-PAOH51 (part number 51307078-100) HART Analog Output Module, operates as a dedicated hardware component for converting controller commands into precise analog field loops within Experion PKS Series-C platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | CC-TAOX51 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.3 kg |
| Dimensions | 120 mm x 85 mm x 40 mm |
| Operating Temp | -20 to +55 deg C |
| Power Consumption | 60 W |
| Part Number | 51307078-100 / CC-PAOH51 Rev A |
| Channels | 16 independent channels |
| Output Signal Type | 4-20 mA current output |
| Communication Interfaces | RS485, Modbus RTU |
| Accuracy | +/- 0.1% typical |
| Isolation | Channel-to-channel and system isolation |
| Mounting | DIN rail installation |
Channel-to-Channel Isolation and 4-20 mA HART Loop Protocol Execution
The Honeywell CC-TAOX51 provides physical termination assembly paths utilizing a 4-20 mA current drive topology across 16 independent channels supporting the 4-20 mA HART loop protocol. The layout embeds functional channel-to-channel isolation networks alongside dedicated system-side galvanic boundaries to block high-voltage transient spikes originating in the field from propagating back to the central processing backplane. In addition to standard analog drive circuitry, the hardware incorporates onboard communication physical layers supporting RS485 and Modbus RTU protocols to facilitate auxiliary telemetry routing alongside primary process control operations.
Frequently Asked Questions
Q: How is the serial communication interface configured on this terminal assembly?
A: The onboard RS485 interface utilizes Modbus RTU protocol rules to act as a localized data link, allowing upstream nodes or monitoring tools to extract real-time diagnostic states directly from the module termination assembly.
Q: What action does the output channel execute if system communication is lost?
A: Upon a deterministic loss of the backplane data stream, the individual channel circuits transition their respective 4-20 mA outputs to a predefined, hardware-configured fallback state or hold the last valid current value until CPU communication resumes.
Field Installation Guidelines
- Snap the assembly onto the standard industrial DIN rail within the local enclosure, checking that both top and bottom tension clips are fully engaged to prevent mechanical shifting.
- Terminate all 4-20 mA loop shield drains at a single common ground bus inside the cabinet, keeping the outer shield jacket continuously insulated throughout the conduit path to prevent ground loop offsets.
- Confirm that the aggregate power dissipation of adjacent DIN rail components does not exceed the structural cooling capabilities of the cabinet layout, leaving a minimum vertical clearance zone above the assembly to permit unhindered airflow.
- Route field output signal cables through dedicated wire raceways separated from AC power conductors by at least 200 mm to prevent electromagnetic coupling.
- Verify that field wiring connections comply with the terminal assignments for the corresponding 16-channel analog output arrangement before energizing loop power.
How to Get a Quote
Order Tracking
Shipping Carriers
Refund Policy and Conditions
Warranty Conditions
Related Products
- Choosing a selection results in a full page refresh.