{"product_id":"cc-tcnt01-honeywell-experion-c300-controller-module","title":"CC-TCNT01 Honeywell Experion C300 Controller Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TCNT01 51308307-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TCNT01\u003c\/strong\u003e C300 Controller Module, operates as a dedicated hardware component for deterministic process control and real-time data processing within Honeywell Experion PKS networks. It executes user-configured control strategies, manages I\/O link scans, and coordinates system communication across redundant control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TCNT01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51308307-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C300 form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 24 VDC backplane distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eHigh-speed embedded processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Architecture\u003c\/td\u003e\n\u003ctd\u003eIntegrated RAM and flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003eFault Tolerant Ethernet (FTE), I\/O Link, ControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eUniversal Control Network chassis \/ C300 carrier assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TCNT01 processing unit interfaces directly with input\/output networks to manage cyclic data execution from field instrumentation using 4-20 mA HART loop protocol configurations. Internal galvanically isolated bus drivers prevent field-side common-mode noise, ground potential variances, and cross-channel voltage spikes from propagating into the central processing core. By decoupling high-speed control logic circuits from I\/O bus lines, the controller maintains continuous execution loops, processes HART digital pass-through records, and preserves signal integrity across distributed field drops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the CC-TCNT01 controller module handle redundant failover operations?\u003c\/p\u003e\n\u003cp\u003eA: In a redundant C300 pair configuration, the active CC-TCNT01 mirrors its memory state to the secondary module via dedicated control network links, enabling deterministic, bumpless failover within a single execution cycle.\u003c\/p\u003e\n\u003cp\u003eQ: What power rail input is required to operate the CC-TCNT01 module?\u003c\/p\u003e\n\u003cp\u003eA: The module operates from a regulated 24 VDC power supply distributed directly through the carrier chassis backplane.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CC-TCNT01 be installed or replaced while the backplane power is active?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CC-TCNT01 supports online insertion and removal (hot-swapping) on energized C300 carrier bases, provided safety procedures for primary\/secondary controller states are maintained.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the backplane multi-pin connectors and guide tracks on the carrier chassis to verify that no physical debris or bent pins are present prior to insertion.\u003c\/li\u003e\n\u003cli\u003eAlign the card edge of the CC-TCNT01 module with the mounting slot channels of the assigned C300 base assembly.\u003c\/li\u003e\n\u003cli\u003ePush the module firmly into the slot until the backplane connectors fully seat and the mechanical retention latches snap shut.\u003c\/li\u003e\n\u003cli\u003eVerify that all Fault Tolerant Ethernet (FTE) media cables and I\/O Link interfaces are properly secured with minimum bend radii respected.\u003c\/li\u003e\n\u003cli\u003eConnect the enclosure earthing point to the master grounding bus bar using low-impedance copper conductors to suppress electromagnetic field interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52346573357352,"sku":"CC-TCNT01 51308307-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-TCNT0151308307-175_Cocoai.png?v=1788853057","url":"https:\/\/www.powerdcs.com\/products\/cc-tcnt01-honeywell-experion-c300-controller-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}