FC-BSDOL-04UNI | Honeywell | Range-Setting Module

Specifications

  • Manufacturer: Honeywell

  • Product No.: FS-BSDOL-04UNI

  • Condition: 10 Items in Stock

  • Product Type: Range-Setting Modules

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 400g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product details

Description

Configured for current sense range setting and output loop calibration in Honeywell Safety Manager SC platforms, the Honeywell FC-BSDOL-04UNI (FC-BSDOL-04UNI Range-Setting Module) provides direct physical/electrical execution across four loop-monitored output channels. It mounts directly onto the programming connectors (Px) of the I/O backplane to adjust lead breakage detection thresholds for connected output modules.

Hardware Specifications

Parameter Specification
Model FC-BSDOL-04UNI
Brand Honeywell
Origin USA
Weight 0.4 kg
Dimensions 120 mm x 60 mm x 40 mm
Operating Temp -20 to +70 deg C (-4 to +158 deg F)
Power Consumption < 5 W
Operating Voltage 24 VDC
Range Setting Resolution Up to +/-0.596 accuracy
Monitored Channels 4 loop-monitored output channels
Communication Interface RS-485
System Compatibility Honeywell Safety Manager SC, SDOL systems (e.g., SDOL-0424)

Process Control & DCS Signal Processing Characteristics

The FC-BSDOL-04UNI module integrates precise current sense adjustments to prevent false lead breakage detection in field output circuits. Built for integration with 4-20 mA HART loop protocol architectures and discrete safety driver outputs, the hardware provides channel-to-channel isolation to prevent electrical fault propagation across field wiring loops. In redundant output configurations involving SDOL-0424 modules, a single FC-BSDOL-04UNI serves both primary and secondary channels to maintain consistent range calibration across the safety system.

Frequently Asked Questions

Q: How is the FC-BSDOL-04UNI module physically mounted to the Safety Manager chassis?

A: The module connects directly to the dedicated programming connector (Px) interface on the I/O backplane without external wiring harnesses.

Q: How does the module handle range-setting operations in redundant output configurations?

A: In redundant SDOL module setups, a single FC-BSDOL-04UNI module provides unified range setting across both redundant output channels.

Q: Does the RS-485 communication interface require separate power cabling?

A: No, operating power of 24 VDC and communication paths are routed through the backplane programming connector interface.

Field Installation Guidelines

  • Backplane Connection: Align the board interface with the dedicated programming connector (Px) on the Safety Manager SC backplane. Press firmly to seat the pins, ensuring no pins are bent during insertion.
  • Redundancy Setup: Verify that the single FC-BSDOL-04UNI module is correctly mapped across both SDOL-0424 modules when configured for redundant output operation.
  • Grounding & Shielding: Ensure the rack chassis grounding strip is connected to the cabinet earth bar to prevent common-mode electrical noise from affecting range-setting accuracy.
  • Thermal Management: Maintain adequate clearance around the module to allow convective heat dissipation within the rated operating temperature limit of -20 to +70 deg C.