FC-TSRO-0824 CC V1.1 | Honeywell | Digital Output Module

Specifications

  • Manufacturer: Honeywell

  • Product No.: FC-TSRO-0824 CC V1.1

  • Condition: 10 Items in Stock

  • Product Type: Digital Output Modules

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 350g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product details

Description

The Honeywell FC-TSRO-0824 CC V1.1, also cataloged as the FC-TSRO-0824 Digital Output Field Termination Assembly, operates as a dedicated hardware component for 24 VDC digital discrete signal switching and relay interface execution within Honeywell Safety Manager platforms. Designed with 8 independent output channels, the assembly executes discrete control commands while isolating backplane logic from field-side electrical disturbances. The module functions within an operating temperature range of -20 to +70 deg C to ensure uninterrupted loop execution.

Hardware Specifications

Parameter Specification
Model FC-TSRO-0824 CC V1.1
Brand Honeywell
Origin USA
Weight 0.35 kg
Dimensions 15.0 cm x 8.0 cm x 3.5 cm
Operating Temp -20 to +70 deg C
Power Consumption 24 VDC field loop powered
Module Type Digital Output Field Termination Assembly
Channels 8 relay / digital output channels
Nominal Voltage 24 VDC
Isolation Galvanic channel-to-channel isolation

Channel-to-Channel Isolation & Output Loop Execution

The FC-TSRO-0824 CC V1.1 executes discrete switching signals via isolated physical output channels to drive solenoids, relays, and field actuators. Featuring galvanic channel-to-channel isolation between internal backplane control logic and field-side wiring, the module prevents transient inductive kickbacks from disrupting adjacent digital logic or 4-20 mA HART loop protocol instruments. Integrated suppression networks stabilize line switching response during high-duty output toggling across the DCS network interface.

Frequently Asked Questions

Q: What power source is required to drive output loads connected to the FC-TSRO-0824 CC V1.1?

A: Field output channels require an external regulated 24 VDC power feed connected directly through the field termination assembly screw terminals.

Q: How does the module handle inductive switching noise from external relays and field valves?

A: Internal galvanic channel-to-channel isolation stages decouple backplane logic circuits from field-side voltage spikes and switching transients.

Q: Can output wiring be serviced while the unit is energized?

A: Field power feeds must be isolated prior to wiring maintenance to prevent accidental short circuits or transient damage to output contacts.

Field Installation Guidelines

  1. Disconnect all 24 VDC field power sources before attaching or removing terminal connections on the FC-TSRO-0824 CC V1.1 module.
  2. Route discrete output conductors in dedicated cable trays separated from high-voltage AC lines to minimize electromagnetic cross-talk.
  3. Ensure terminal block retention screws are torqued properly to maintain steady electrical contact and vibration resistance.
  4. Connect cable shielding to the main cabinet earth ground point using a single-point connection strategy.
  5. Verify cabinet ambient environmental conditions stay within -20 to +70 deg C to ensure uninterrupted switching performance.

How to Get a Quote

Order Tracking

Shipping Carriers

Refund Policy and Conditions

Warranty Conditions