FC-TSRO-0824 CC V1.1 | Honeywell | Digital Output Module
Specifications
Manufacturer: Honeywell
Product No.: FC-TSRO-0824 CC V1.1
Condition: 10 Items in Stock
Product Type: Digital Output Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Product details
Description
The Honeywell FC-TSRO-0824 CC V1.1, also cataloged as the FC-TSRO-0824 Digital Output Field Termination Assembly, operates as a dedicated hardware component for 24 VDC digital discrete signal switching and relay interface execution within Honeywell Safety Manager platforms. Designed with 8 independent output channels, the assembly executes discrete control commands while isolating backplane logic from field-side electrical disturbances. The module functions within an operating temperature range of -20 to +70 deg C to ensure uninterrupted loop execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FC-TSRO-0824 CC V1.1 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.35 kg |
| Dimensions | 15.0 cm x 8.0 cm x 3.5 cm |
| Operating Temp | -20 to +70 deg C |
| Power Consumption | 24 VDC field loop powered |
| Module Type | Digital Output Field Termination Assembly |
| Channels | 8 relay / digital output channels |
| Nominal Voltage | 24 VDC |
| Isolation | Galvanic channel-to-channel isolation |
Channel-to-Channel Isolation & Output Loop Execution
The FC-TSRO-0824 CC V1.1 executes discrete switching signals via isolated physical output channels to drive solenoids, relays, and field actuators. Featuring galvanic channel-to-channel isolation between internal backplane control logic and field-side wiring, the module prevents transient inductive kickbacks from disrupting adjacent digital logic or 4-20 mA HART loop protocol instruments. Integrated suppression networks stabilize line switching response during high-duty output toggling across the DCS network interface.
Frequently Asked Questions
Q: What power source is required to drive output loads connected to the FC-TSRO-0824 CC V1.1?
A: Field output channels require an external regulated 24 VDC power feed connected directly through the field termination assembly screw terminals.
Q: How does the module handle inductive switching noise from external relays and field valves?
A: Internal galvanic channel-to-channel isolation stages decouple backplane logic circuits from field-side voltage spikes and switching transients.
Q: Can output wiring be serviced while the unit is energized?
A: Field power feeds must be isolated prior to wiring maintenance to prevent accidental short circuits or transient damage to output contacts.
Field Installation Guidelines
- Disconnect all 24 VDC field power sources before attaching or removing terminal connections on the FC-TSRO-0824 CC V1.1 module.
- Route discrete output conductors in dedicated cable trays separated from high-voltage AC lines to minimize electromagnetic cross-talk.
- Ensure terminal block retention screws are torqued properly to maintain steady electrical contact and vibration resistance.
- Connect cable shielding to the main cabinet earth ground point using a single-point connection strategy.
- Verify cabinet ambient environmental conditions stay within -20 to +70 deg C to ensure uninterrupted switching performance.
How to Get a Quote
Order Tracking
Shipping Carriers
Refund Policy and Conditions
Warranty Conditions
Related Products
- Choosing a selection results in a full page refresh.