{"product_id":"fc-tsro-0824-cc-v1-1-honeywell-digital-output-module","title":"FC-TSRO-0824 CC V1.1 | Honeywell | Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TSRO-0824 CC V1.1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-TSRO-0824\u003c\/strong\u003e Digital Output Field Termination Assembly, operates as a dedicated hardware component for 24 VDC digital discrete signal switching and relay interface execution within Honeywell Safety Manager platforms. Designed with 8 independent output channels, the assembly executes discrete control commands while isolating backplane logic from field-side electrical disturbances. The module functions within an operating temperature range of -20 to +70 deg C to ensure uninterrupted loop execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TSRO-0824 CC V1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 8.0 cm x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC field loop powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 relay \/ digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic channel-to-channel isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Output Loop Execution\u003c\/h3\u003e\n\u003cp\u003eThe FC-TSRO-0824 CC V1.1 executes discrete switching signals via isolated physical output channels to drive solenoids, relays, and field actuators. Featuring galvanic channel-to-channel isolation between internal backplane control logic and field-side wiring, the module prevents transient inductive kickbacks from disrupting adjacent digital logic or 4-20 mA HART loop protocol instruments. Integrated suppression networks stabilize line switching response during high-duty output toggling across the DCS network interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power source is required to drive output loads connected to the FC-TSRO-0824 CC V1.1?\u003c\/p\u003e\n\u003cp\u003eA: Field output channels require an external regulated 24 VDC power feed connected directly through the field termination assembly screw terminals.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle inductive switching noise from external relays and field valves?\u003c\/p\u003e\n\u003cp\u003eA: Internal galvanic channel-to-channel isolation stages decouple backplane logic circuits from field-side voltage spikes and switching transients.\u003c\/p\u003e\n\u003cp\u003eQ: Can output wiring be serviced while the unit is energized?\u003c\/p\u003e\n\u003cp\u003eA: Field power feeds must be isolated prior to wiring maintenance to prevent accidental short circuits or transient damage to output contacts.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all 24 VDC field power sources before attaching or removing terminal connections on the FC-TSRO-0824 CC V1.1 module.\u003c\/li\u003e\n\u003cli\u003eRoute discrete output conductors in dedicated cable trays separated from high-voltage AC lines to minimize electromagnetic cross-talk.\u003c\/li\u003e\n\u003cli\u003eEnsure terminal block retention screws are torqued properly to maintain steady electrical contact and vibration resistance.\u003c\/li\u003e\n\u003cli\u003eConnect cable shielding to the main cabinet earth ground point using a single-point connection strategy.\u003c\/li\u003e\n\u003cli\u003eVerify cabinet ambient environmental conditions stay within -20 to +70 deg C to ensure uninterrupted switching performance.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52636385280296,"sku":"FC-TSRO-0824 CC V1.1","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FC-TSRO-0824.jpg?v=1789978618","url":"https:\/\/www.powerdcs.com\/products\/fc-tsro-0824-cc-v1-1-honeywell-digital-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}