{"product_id":"fc-tuio11-safety-universal-i-o-module-honeywell","title":"FC-TUIO11 Safety Universal I\/O Module | Honeywell","description":"\u003cp\u003eConfigured for universal field signal execution in Honeywell Safety Manager and Fail Safe Controller systems, the \u003cstrong\u003eHoneywell FC-TUIO11\u003c\/strong\u003e (\u003cstrong\u003eFC-TUIO11\u003c\/strong\u003e Safety Universal I\/O Module) provides direct physical and electrical interface functions for safety-related input and output channels. The hardware manages bidirectional signal conditioning and channel routing, executing discrete and analog safety loop execution across controller backplane assemblies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TUIO11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.1 x 18.8 x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.22 W at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e55 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Safe Voltage (Um)\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Limits (Uo \/ Io \/ Po)\u003c\/td\u003e\n\u003ctd\u003e25.2 V \/ 113.13 mA \/ 712.7 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Signal Processing Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe FC-TUIO11 safety universal I\/O module incorporates high-density channel-to-channel isolation to prevent loop interference and ground loops between field sensors and the logic solver backplane. Fully compatible with standard 4-20 mA HART loop protocol field devices and discrete safety loops, the module filters high-frequency electromagnetic noise while maintaining defined safety voltage limits (Um = 250 V). Integrated current limiting protects central backplane communication buses from unexpected field-side overvoltage conditions or short circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the nominal power supply requirements for the FC-TUIO11 module?\u003c\/p\u003e\n\u003cp\u003eA: The module requires a nominal 24 VDC supply, drawing a rated current of 55 mA with a total power consumption of 1.22 W.\u003c\/p\u003e\n\u003cp\u003eQ: What entity parameters define the maximum safety limits of the field output channels?\u003c\/p\u003e\n\u003cp\u003eA: The hardware specifies a maximum safe voltage (Um) of 250 V, with output safety parameters defined as Uo = 25.2 V, Io = 113.13 mA, and Po = 712.7 mW.\u003c\/p\u003e\n\u003cp\u003eQ: How is field signal isolation maintained across the universal channels?\u003c\/p\u003e\n\u003cp\u003eA: Universal channels utilize galvanic channel-to-channel isolation to decouple field loop circuits from internal logic circuits and neighboring I\/O channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Align the module enclosure with the baseplate chassis slots in the safety cabinet and press firmly until the locking mechanism fully latches into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring \u0026amp; Termination:\u003c\/strong\u003e Connect field loop conductors to the dedicated terminal block pins. Verify cable wire strip lengths and ensure proper polarity alignment for 24 VDC circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Connect field wiring cable shields directly to the cabinet main earth grounding bar using low-impedance grounding clamps to prevent noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route low-voltage universal I\/O cables in separate wireways from high-voltage AC power distribution lines, maintaining at least 30 cm clearance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52715510858024,"sku":"FC-TUIO11 51306920-176","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FC-TUIO11.jpg?v=1790064044","url":"https:\/\/www.powerdcs.com\/products\/fc-tuio11-safety-universal-i-o-module-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}