{"product_id":"foxboro-fbm214-rh927ah-i-a-series-hart-communication-analog-input-module","title":"Foxboro FBM214 RH927AH I\/A Series HART Communication Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eFoxboro FBM214 RH927AH\u003c\/strong\u003e is an 8-channel isolated analog input module for Foxboro I\/A Series systems. It acquires 4-20 mA DC signals with 15-bit resolution and +\/- 0.03% of span accuracy, while supporting bidirectional HART communication (Versions 5, 6, and 7) and redundant pair configurations over a 2 Mbps redundant Module Fieldbus.\u003c\/p\u003e\n\u003ch3\u003eHART Communication, Isolation, and Redundancy\u003c\/h3\u003e\n\u003cp\u003eEach of the 8 galvanically isolated channels reads a 4-20 mA DC signal and supports HART Versions 5, 6, and 7 for field instrument configuration and diagnostic data exchange. Dedicated per-channel microprocessing and communication over the 2 Mbps redundant Module Fieldbus support deterministic updates, while redundant module pairs enable bumpless failover when configured.\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation is rated at 600 VAC input-to-bus and input-to-ground to separate field loops from control circuits. Built-in diagnostics check internal hardware health as well as sensor burnout and short circuit conditions.\u003c\/p\u003e\n\u003ch3\u003ePower, Environmental Limits, and Installation Notes\u003c\/h3\u003e\n\u003cp\u003eMaximum power consumption is 3.5 W, with an operating temperature range of -20 to 70 deg C and a storage temperature range of -40 to 85 deg C.\u003c\/p\u003e\n\u003cp\u003eFor installation, power down the control system before inserting or removing the module from the baseplate, and follow ESD-safe handling practices. Use shielded twisted-pair cabling for analog inputs, ground cable shields at the field termination assembly (FTA) or per plant grounding rules, and leave clearance for airflow in dense racks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM214 (RH927AH); listed as FBM 214b (RH927AH) in specification table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Foxboro by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eFoxboro I\/A Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHART Communication Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Protocol\u003c\/td\u003e\n\u003ctd\u003eVersions 5, 6, and 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.03% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e15 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e600 VAC (input-to-bus and input-to-ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Bus\u003c\/td\u003e\n\u003ctd\u003e2 Mbps redundant Module Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eInternal self-test, sensor burnout, short circuit detection, hardware health\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.5 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Which HART protocol versions does the Foxboro FBM214 RH927AH support?\u003c\/p\u003e\n\u003cp\u003eA: It supports HART Versions 5, 6, and 7 for bidirectional communication with compatible field instruments in Foxboro I\/A Series systems.\u003c\/p\u003e\n\u003cp\u003eQ: Can two FBM214 modules operate in a redundant pair?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports redundant pair configurations for bumpless failover when a primary module experiences a fault.\u003c\/p\u003e\n\u003cp\u003eQ: What wiring and power precautions apply during installation?\u003c\/p\u003e\n\u003cp\u003eA: Power down the control system before baseplate insertion or removal, observe ESD handling precautions, and wire analog inputs using shielded twisted-pair cable grounded at the FTA or per plant grounding standards.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":68249757942056,"sku":"FBM214 RH927AH","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FBM214P0922VT_7d46f684-32eb-4985-ad5b-7814746a972f.jpg?v=1795144520","url":"https:\/\/www.powerdcs.com\/products\/foxboro-fbm214-rh927ah-i-a-series-hart-communication-analog-input-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}