{"product_id":"fs-cpchas-0001-honeywell-chassis-for-control-processor","title":"FS-CPCHAS-0001 | Honeywell | Chassis for Control Processor","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-CPCHAS-0001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFS-CPCHAS-0001\u003c\/strong\u003e Chassis for Control Processor, operates as a dedicated hardware component for mechanical housing and backplane power distribution within Honeywell Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-CPCHAS-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.80 kg (Shipping weight: 8.00 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.00 cm x 48.26 cm x 17.70 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5V-1: 0.05 A; 5V-2: 0.05 A (Quiescent backplane current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ FSC Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Type\u003c\/td\u003e\n\u003ctd\u003eRack-mountable control processor enclosure assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rail Inputs\u003c\/td\u003e\n\u003ctd\u003eDual redundant 5 VDC internal power rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation and 4-20 mA HART Loop Protocol Integration\u003c\/h3\u003e\n\u003cp\u003eThe rack chassis incorporates isolated backplane power distribution tracks engineered to deliver dual-redundant 5 VDC logic supply feeds to plugged control processor units. High-density dielectric insulation between backplane traces provides physical channel-to-channel isolation across internal data buses. This shielding structure suppresses common-mode noise propagation and prevents power switching transients from corrupting analog input channels carrying 4-20 mA HART loop protocol signals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary internal power rails are routed through the FS-CPCHAS-0001 backplane?\u003c\/p\u003e\n\u003cp\u003eA: The backplane provides dual independent 5 VDC power rails (designated 5V-1 and 5V-2), drawing a baseline current of 0.05 A per line to feed control processor modules.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping or card replacement supported within the control processor chassis?\u003c\/p\u003e\n\u003cp\u003eA: Module replacement capabilities depend on the specific redundancy configuration; in redundant controller setups, an offline module may be extracted without interrupting system execution, provided ESD precautions are observed.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting form factor is supported by the physical dimensions?\u003c\/p\u003e\n\u003cp\u003eA: The chassis width of 48.26 cm corresponds to a standard 19-inch industrial rack enclosure with an overall height profile of 17.70 cm (4 U rack height).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the chassis assembly into a standard 19-inch cabinet frame using four front-panel mounting bolts to establish chassis ground continuity.\u003c\/li\u003e\n\u003cli\u003eVerify that both 5V-1 and 5V-2 primary power supply feeds are properly connected to the backplane terminal blocks prior to inserting processor modules.\u003c\/li\u003e\n\u003cli\u003eEnsure a minimum clearance of 1 U above and below the chassis assembly to maintain adequate convection airflow for processor heat dissipation.\u003c\/li\u003e\n\u003cli\u003eBond the enclosure chassis ground lug directly to the main cabinet protective earth (PE) bus using a low-impedance copper grounding strap.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52829358981416,"sku":"FS-CPCHAS-0001","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FS-CPCHAS-00011.png?v=1790149513","url":"https:\/\/www.powerdcs.com\/products\/fs-cpchas-0001-honeywell-chassis-for-control-processor","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}