{"product_id":"fs-sicc-0001-l7-system-interconnection-cable-honeywell","title":"FS-SICC-0001\/L7 System Interconnection Cable | Honeywell","description":"\u003cp\u003eConfigured for high-integrity inter-rack signal routing in FSC and Experion systems, the \u003cstrong\u003eHoneywell FS-SICC-0001\/L7\u003c\/strong\u003e (\u003cstrong\u003eFS-SICC-0001\u003c\/strong\u003e System Interconnection Cable) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-SICC-0001\/L7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eOuter diameter approx. 9.93 mm x 7 m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive interconnect assembly (Zero internal power draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e20-core, AWG 22 (approx. 0.34 mm2) shielded interconnection cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eDouble-shielded (foil and braid) for EMI\/RFI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eFactory-terminated connectors for Honeywell chassis modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell FSC and Experion Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe FS-SICC-0001\/L7 cable assembly incorporates channel-to-channel isolation principles to suppress electromagnetic interference and radio frequency noise across industrial control environments. Utilizing double-shielded AWG 22 conductors, the physical cable layer limits signal attenuation and cross-talk during parallel routing. The assembly transports discrete safety telemetry and 4-20 mA HART loop protocol field signals between central processing racks and remote termination sub-assemblies without line distortion over the 7 m span.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FS-SICC-0001\/L7 cable be disconnected while the host system remains powered?\u003c\/p\u003e\n\u003cp\u003eA: Disconnection during active operation is permissible only within parallel redundant communication configurations; removing a single-channel cable severs active I\/O communication to the central controller.\u003c\/p\u003e\n\u003cp\u003eQ: How does double-shielding impact signal integrity in high-EMI noise environments?\u003c\/p\u003e\n\u003cp\u003eA: The outer foil and braided shield layers isolate internal AWG 22 conductors from external high-frequency electrical fields, preventing induced voltages from corrupting low-level analog loops.\u003c\/p\u003e\n\u003cp\u003eQ: What is the conductor sizing used inside the cable assembly?\u003c\/p\u003e\n\u003cp\u003eA: The cable utilizes 20-core AWG 22 (approx. 0.34 mm2) stranded copper conductors for flexible cabinet wireway installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the cable assembly through dedicated wire trays or conduit, maintaining a minimum static bending radius of 60 mm to avoid damaging the outer jacket or internal foil shield.\u003c\/li\u003e\n\u003cli\u003eAlign factory-terminated pin headers precisely with chassis module connectors before applying seating force, then secure mechanical retention screws to maintain a vibration-proof electrical contact.\u003c\/li\u003e\n\u003cli\u003eEnsure shield drain terminations bond to the cabinet main earth bar at a single grounding point to eliminate ground potential loops.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum 30 cm separation distance between the interconnection cable and high-voltage AC power wiring within cabinet raceways.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52829073867048,"sku":"FS-SICC-0001\/L7","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FC-SICC-0001L101_Cocoai_d15fe57c-8060-48eb-8231-146b89f2961f.png?v=1790149211","url":"https:\/\/www.powerdcs.com\/products\/fs-sicc-0001-l7-system-interconnection-cable-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}