GE Fanuc F35E00VFHF8FH6TM6TPXX Profibus-DP Network Interface Unit

Specifications

  • Manufacturer: GE

  • Product No.: F35E00VFHF8FH6TM6TPXX

  • Condition: 10 Items in Stock

  • Product Type: Profibus-DP Network Interface Unit

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 4000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product details

Description

GE Fanuc F35E00VFHF8FH6TM6TPXX Module

Brand New & Original | Fast Delivery | PLC Automation Module


Product Summary

  • Brand: GE Fanuc

  • Model / Item No.: F35E00VFHF8FH6TM6TPXX

  • Condition: Brand New and Original

  • Warranty: 1 Year

  • Certificate: COO (Certificate of Origin)

  • Stock Availability: 7 units in stock

  • Origin: USA

  • Shipping Port: Dammam, Saudi Arabia

  • Lead Time: 1–3 Working Days

  • Payment Methods: T/T, Western Union, Credit Card

  • Product Type: PLC Module

  • Highlight: Competitive Price | Immediate Delivery | GE Quality Assurance


Product Description

The GE Fanuc F35E00VFHF8FH6TM6TPXX is a high-quality, industrial-grade PLC module designed for seamless integration into automation systems requiring reliable and efficient control. It supports advanced communication features and offers optimal performance in demanding applications.


Ethernet Global Data Configuration (Overview)

Before setting up Ethernet Global Data (EGD) exchanges between PLCs, the following information must be gathered for proper configuration:

  1. Define Data Requirements

    • Identify what data needs to be produced and consumed by each PLC.

  2. IP Address Collection

    • List the IP addresses for all Ethernet Interfaces used in the PLCs involved in data exchange.

  3. Group Assignment

    • Determine up to 32 groups of devices that will participate in EGD exchanges.

  4. Exchange Timing

    • Set appropriate repetition rates and timeout periods for data transmissions.

  5. Exchange Content

    • In each producer PLC, define the content of the exchanges.

    • In each consumer PLC, specify the data ranges to receive the information.

  6. Selective Consumption

    • It is not required for consumer devices to use all data from a produced exchange.

    • Consumers can be configured to ignore specific data ranges within an exchange.


Why Choose This Module?

  • Fully compatible with GE Fanuc automation systems

  • Fast delivery and easy integration

  • Ideal for industrial environments requiring dependable PLC communication

  • Backed by warranty and certification

 

How to Get a Quote

Order Tracking

Shipping Carriers

Refund Policy and Conditions

Warranty Conditions

Related Products