{"product_id":"ge-fanuc-f35n03hahg8gh6tm8hp6tu5fw6d-profibus-dp-network-interface-unit","title":"GE Fanuc F35N03HAHG8GH6TM8HP6TU5FW6D Profibus-DP Network Interface Unit","description":"\u003ch2\u003e\u003cstrong\u003eGE Multilin F35 Feeder Protection Relay\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive, Scalable Protection \u0026amp; Control for Multi-Feeder Systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a member of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Relay (UR) Family\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand delivers cost-effective\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efeeder protection, control, and metering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efive feeders with busbar voltage measurement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esix feeders without\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eit—within a single integrated package. It can function as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandalone device\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor as part of a fully automated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esubstation control system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e✅\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCertified IEC 61850 Ed. 1 \u0026amp; Ed. 2 Support\u003c\/strong\u003e\u003cbr\u003eFull settings via SCL files with flexible process bus support:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIEC 61850-9-2LE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIEC 61869\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIEC 61850-9-2 HardFiber\u003cbr\u003eEnsures seamless\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einteroperability\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edevice management optimization\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereduced ownership costs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e✅\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRoutable GOOSE (R-GOOSE)\u003c\/strong\u003e\u003cbr\u003eEnables GOOSE messages\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebeyond the substation\u003c\/strong\u003e, supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewide-area protection and control\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e✅\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAdvanced Fault \u0026amp; Disturbance Recording\u003c\/strong\u003e\u003cbr\u003eIncludes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal relay operating signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enhanced diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e✅\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCyberSentry™ Cybersecurity Suite\u003c\/strong\u003e\u003cbr\u003eHelps meet modern\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustry cybersecurity standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e✅\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFlexible Communication Options\u003c\/strong\u003e\u003cbr\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eserial and Ethernet interfaces\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emultiple protocols\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor streamlined system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e✅\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWaveform Capture Compatibility\u003c\/strong\u003e\u003cbr\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCOMTRADE 2013\u003c\/strong\u003e, simplifying fault record management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e✅\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModular \u0026amp; Flexible I\/O\u003c\/strong\u003e\u003cbr\u003eIncludes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density I\/O\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprogrammable logic\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecustomization options\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor diverse applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e✅\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntegrated Full-Color Display\u003c\/strong\u003e\u003cbr\u003eOffers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time bay visualization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBay mimic screen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGraphical phasor visualization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnnunciator functionality for local monitoring and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary protection and control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emultiple distribution feeders\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistribution load shedding schemes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etriggered by voltage\/frequency thresholds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBusblocking and interlocking schemes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThrowover schemes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(bus transfer applications)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed Generation (DG) Interconnect Protection\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eactive and passive anti-islanding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin F35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombines flexible architecture, advanced communication protocols, and powerful protection functions, making it the ideal solution for modern distribution substations requiring high-performance and scalable protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":50425298026792,"sku":"F35N03HAHG8GH6TM8HP6TU5FW6D","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/F35N03HAHG8GH6TM8HP6TU5FW6D1.jpg?v=1753059579","url":"https:\/\/www.powerdcs.com\/products\/ge-fanuc-f35n03hahg8gh6tm8hp6tu5fw6d-profibus-dp-network-interface-unit","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}